background image

USER MANUAL

JEFC100V10B Series

100L

 V-PUMP AIR  COMPRESSOR 

 3HP 

 10Bar 

 Direct Drive

www.jeffersontools.com

8

 

 

Read and ensure that you understand all of the operating instructions, safety precautions and warnings in this Instruction  

 

 

Manual before operating or maintaining this compressor. Most accidents that result from compressor operation and  

 

 

 

maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by   

 

 

recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures.  Hazards   

 

 

that must be avoided to prevent bodily injury or machine damage are identified by warnings on the compressor and in this  

 

 

Instruction Manual. Never use this compressor or modify it in any way that has not been specifically recommended by the  

 

 

manufacturer. Contact a qualified electrician for advice on any issues relating to electrical safety in your working environment.

ELECTRICAL SAFETY

Ensure that you check the equipment thoroughly to ensure it is safe and fit for purpose before each use.  It is important that 
you inspect all plugs, sockets, power cables and electrical fittings for wear and damage and repair or replace any defective 
components.  The risk of electric shock can be minimised by the correct use of the appropriate electrical safety devices. 

• 

We recommend that you fit a 

Residual Current Circuit Breaker (RCCB)

 in the main distribution board and that a 

Residual Current Device 

(RCD)

 is used when operating this equipment. 

• 

The 

Electricity at Work Act 1989 

includes legislation that places legal implications on employers to ensure the safety of electrical devices 

in the workplace. The regulations dictate that all portable equipment must be inspected regularly and tested to ensure that it is safe for use. 
'Portable equipment' means any electrical item that can be moved and this is often referred to as 

Portable Appliance Testing (PAT)

. PAT 

testing should be carried out regularly on this equipment by trained, authorised personnel, as required by the legislation.  

• 

The 

Health and Safety at Work Act 1974

 states that it is the responsibility of the owner of electrical appliances to ensure that both the 

equipment and working environments are maintained to ensure safe operation at all times.   

• 

Check that all equipment cables are secure, correctly insulated, free from damage, and protected against short circuit and overload before 
connecting to the power supply. Do not use worn or damaged cables, plugs, sockets or other fittings.  

• 

Ensure that the power supply matches voltage requirements specified on the equipment and that the plug is wired correctly and fitted with 
the correct fuse.  

• 

If the electrical fuse blows, ensure it is replaced by an identical type of fuse with the same rating.  

• 

Never pull or manoeuvre this equipment into position using the power cable (move using the handle).  

• 

Ensure the power cable is kept away from heat, oil and sharp edges. 

• 

We recommend that the equipment is connected directly to the power supply without the use of extension leads as the resulting voltage drop 
can reduce motor and pump performance. 

• 

Always disconnect the compressor from the power source and remove the compressed air from the air tank before servicing, inspecting, 
maintaining, cleaning, replacing or checking any parts. 

• 

Do not carry the compressor while it is connected to its power source or when the air tank is filled with compressed air. Be sure the pressure 
switch is in the 

“Off”

 position before connecting the compressor to its power source. 

• 

Do not use the compressor in damp / wet conditions.  
 
 

  SAFETY GUIDELINES 

 

Summary of Contents for JEFC100V10B Series

Page 1: ...User Manual v 1 1 JEFC100V10B Series V PUMP DIRECT DRIVE ...

Page 2: ...USER MANUAL JEFC100V10B Series 100L V PUMP AIR COMPRESSOR 3HP 10Bar Direct Drive www jeffersontools com 2 ...

Page 3: ...ation to ensure its correct and safe use We recommend that this manual is read before any operation or before performing any kind of adjustment to the product and prior to any maintenance tasks By following all the general safety instructions contained in this manual you will help to ensure operator safety and extend the potential lifespan of the equipment All photographs and drawings in this manu...

Page 4: ...ansportation handle front rubber mounted feet and rear wheels to assist manoeuvrability Powder coated finish on the tank provides protection against corrosion SPECIFICATIONS JEFC100V10B 230 JEFC100V10B 110 Tank Capacity 100L 100L Input Voltage Frequency 230V 50Hz 110V 50Hz Motor Output 3HP 2 2kW 3HP 2 2kW Plug Type Rated Supply UK 3 Pin 13A UK 3 Pin 16A Cylinders 2 2 Speed 2850rpm 2850rpm Air Disp...

Page 5: ...should it be necessary to transport the unit WARNING Never operate the compressor with only the plastic transportation bung fitted Under normal use internal pressure can expel the bung along with oil from the head possibly leading to damage PLEASE NOTE THE FOLLOWING PHOTOGRAPHS INSTRUCTIONS ARE FOR REFERENCE ONLY AND MAY DIFFER FOR YOUR COMPRESSOR MODEL PLEASE CONTACT JEFFERSON TOOLS IF YOU NEED A...

Page 6: ...11 Airline Coupler Air Outlet 3 Oil Sight Level Glass 12 Tank Pressure Gauge 4 Pump Assembly 13 Working Pressure Gauge 5 Air Filter Assembly x2 14 Non Return Valve 6 Cylinder x2 15 Front Wheel 7 Motor Housing Shroud 16 Drain Valve 8 Pressure Switch ON OFF 17 Rear Wheels 9 Pressure Regulator EQUIPMENT IDENTIFICATION 3 17 2 1 9 10 11 12 14 16 15 13 8 7 4 5 6 ...

Page 7: ...suitable for use This compressor must be used on a flat level surface The maximum safe operating angle in any direction is 10 degrees see Fig 8 Do not operate the compressor on inclines in excess of 10 degrees Serious damage to pump components may result from insufficient lubrication Never use the air compressor on a rooftop or elevated position that could allow the unit to fall or be tipped over ...

Page 8: ...e that all portable equipment must be inspected regularly and tested to ensure that it is safe for use Portable equipment means any electrical item that can be moved and this is often referred to as Portable Appliance Testing PAT PAT testing should be carried out regularly on this equipment by trained authorised personnel as required by the legislation The Health and Safety at Work Act 1974 states...

Page 9: ...otor air vent must be kept clean so that air can freely flow at all times Check for dust build up frequently and clean as required If the equipment appears to be operating unusually making strange noises or otherwise appears defective stop using it immediately and arrange for repairs by a authorized service centre Solvents such as petrol thinner benzine carbon tetrachloride and alcohol may damage ...

Page 10: ...paint in a confined area with the air compressor Operate the air compressor in well ventilated areas free from obstructions Equip areas with fire extinguishers suitable for electrical fires Do not leave nylon material shirts or jumpers on the compressor Store paint thinners and other flammable liquids in approved containers in a secure location away from the work area Minimum clearance 0 5m Maximu...

Page 11: ...e pressure gauge The compressor will now operate automatically The pressure switch stops the motor when the maximum tank pressure is reached and restarts it when the pressure falls below the minimum threshold approx 2 bar 29psi less than the maximum pressure Stopping The Compressor Stop the compressor by moving the main switch to the OFF position The compressed air inside the compressor head will ...

Page 12: ...horised service agent There is a leak from the base of the pressure switch when the compressor is stopped The Non return valve from the tank is leaking Disassemble and clean if necessary replace valve insert Contact your authorised service agent The compressor is noisy with metallic clangs knocks Bearing or piston problem Low oil level Stop the compressor and contact a specialized service technici...

Page 13: ... turned off and disconnected from the power source Allow the compressor pump and other parts to cool off if changing oil after use Ensure compressor is on a flat and level surface Remove fill cap plug and place collection container underneath the oil drain cap Remove the oil drain cap and let the oil drain out Replace the oil cap and be sure to tighten this nut securely you can use some PTFE tape ...

Page 14: ... the European Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal We hereby dec...

Page 15: ...1 Quick Coupler 26 1 Check Valve 3 2 SP Washer 15 1 Pressure Regulator 27 2 Sleeve Nut 4 2 PL Washer 16 1 Pressure Gauge 28 1 Copper Tube 5 2 Spacer 17 1 Pressure Switch 29 4 Hex Nut 6 2 Wheel 18 1 Pressure Gauge 30 4 Pl Washer 7 2 Axle 19 1 Nipple 31 4 Sp Washer 8 1 Drain Ball Valve 20 1 Safety Valve 32 4 Hex Bolt 9 1 Air Tank 21 1 Nipple 33 1 Pump Assembly 10 1 Wheel 22 2 Bushing 11 1 Hex Nut 23...

Page 16: ...ate 42 1 Hex Socket Bolt 7 1 Hex Socket bolt 25 2 Valve Holder 43 1 Centrifugal Switch 8 1 PL washer 26 1 Air Filter Assembly 44 1 Bearing 9 1 Crankshaft 27 3 Cylinder Head 45 1 Rear Cover 10 1 Hex Socket bolt 28 8 Hex Bolt 46 3 Hex Socket Bolt 11 1 Crank case 29 1 Hex Bolt 47 1 Plastic Tray 12 4 Hex Socket bolt 30 1 Hex Bolt 48 1 Fan Blade 13 2 Cylinder gasket 31 1 2 Way Manifold Nipple 49 1 Circ...

Page 17: ...ure Vessels Directive 2014 35 EU as amended Low Voltage Directive 2011 65 EU as amended RoHS Directive Equipment Category Air Compressor Item 8 Product Name Model JEFC100V10B 230 JEFC100V10B 110 100L 3HP 10 Bar V Pump Air Compressor Notified Body Technicka inspekcia a s Trnavska cesta 56 821 01 BRATISLAVA Country Slovakia Phone 421 2 49 208 100 Fax 421 2 49 208 160 Notified Body Number 1354 Measur...

Page 18: ...ded as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect will be corrected by repair or replacement at an authorized Jefferson dealer or repair centre Packaging Freight Costs The customer is responsible for the packaging of the equipment and making it read...

Page 19: ...ctive and in need of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructed in the user manual Where repair is not covered by the warranty a quotation for repair labour costs and return delivery will be sent to the customer normally within 7 working days Note If the re...

Page 20: ...ss Park Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions outlined in this manual to reduce the risk of fire electric shock or personal injury www jeffersontools com www jeffersontools com ...