Table 1:
Section Valid For A Max Length Of 20M Single-Phase
HP
kW
220/230V
110/120V
0,75 - 1
0,65–0,7
1,5
2,5
1,5
1,1
2,5
4
2
1,5
2,5
4 – 6
2,5 - 3
1,8 – 2,2
4
/
The diameter of the extension cable of the 3-phase compressors must be in proportion to its length: see table (tab 2)
Table 2:
Section Valid For A Max Length Of 20M Three-Phase
HP
kW
220/230V
110/120V
0,75 - 1
0,65–0,7
1,5
2,5
1,5
1,1
2,5
4
2
1,5
2,5
4 – 6
2,5 - 3
1,8 – 2,2
4
/
7. WARNING LABELS
Label
Potential Hazard
Prevention
Water directed at electrical connections or switches, or
objects connected to an electrical circuit, could result in
a fatal electrical shock.
Moisture or a liquid of any kind may conduct electricity
and could result in a fatal electrical shock.
Note:
This equipment is not waterproof.
Never attempt to clean the air compressor while it is
running. Direct any water or spray away from electric
outlets and switches.
Keep your air compressor out of the elements and well
sheltered from rain, snow, dew, water or mist of any kind.
Do not use the compressor with the supply cord damaged
or with poor quality connections
Operating the air compressor in an explosive environ-
ment could result in a fire.
Materials placed against or near the air compressor can
interfere with its proper ventilation causing overheating
and possible ignition of the materials.
Improperly stored paint thinners could lead to accidental
ignition. thinners improperly secured could get into the
hands of children or other unqualified persons.
Good air flow is important as both the motor and com-
pressor unit are air cooled. Restrictions to or insufficient
air flow will cause overheating.
Never spray paint in a confined area with the air compres-
sor.
Operate the air compressor in well ventilated areas free
from obstructions. Equip areas with fire extinguishers suit-
able for electrical fires. Do not leave nylon material shirts
or jumpers on the compressor.
Store paint thinners and other flammable liquids in ap-
proved containers, in a secure location away from the
work area.
Minimum clearance 0.5m / Maximum ambient operating
temperature 45°C
This air compressor does not provide breathable air, the
air may be contaminated with mineral based oils and
other contaminants which poses the risk of serious lung
infection and or injury.
Spraying any material without the use of a face mask will
result in the ingestion of foreign substances.
Never try to provide breathing air or refill auxiliary breath-
ing apparatus using this compressor.
Never spray substances in a closed location occupied by
humans or animals always use a face mask when spray-
ing substances
Contact with hot surfaces, such as the cylinder head,
cooling fins or discharge pipe, could result in serious
burns.
These parts will remain hot for some time after the
compressor is shut down.
During operation, touch only the control surfaces of the
air compressor. Keep children and animals far away from
the air compressor at all times. They may not be able to
recognize the hazards of this product.
Allow the air compressor to cool before storage.