![Jedia MMA-400 Series Operating Instructions Manual Download Page 26](http://html1.mh-extra.com/html/jedia/mma-400-series/mma-400-series_operating-instructions-manual_3671932026.webp)
23
CA-42
4가지 종류의 알람(GONG, DING-DONG, 4-TONE1, 4-TONE2)을
선택하기 위한 점퍼입니다.
공장 출하시 DING-DONG으로 설정되어 있습니다.
13.챠임원 선택 점퍼
알람음 동작 시간을 조절하는 볼륨입니다. 동작시간 가변 범위는 약
5 60초 입니다. 공장 출하시 최소 약 5초로 설정되어 있으며 적당한
시간으로 조절하여 사용하십시오.
14.알람음 동작 시간 조절기
Jumper for four kinds of chime selecto(GONG,DING-DONG,
4-TONE1, 4-TONE2)
13.CHIME SELECTOR JUMPERS
Time control for alert sounding variable range of operating time is
5~60 seconds.
Factors factory production is setup 5 seconds.
14.ALERT SOUNDING TIME CONTROL
MODULE TYPE
Applications
Specifications
Signal
CHIME & ALERT SIGNAL MODULE
CA-42
Gong, 2-tone, 4-tone1, 4-tone2
(Switchable)
2-tone, Yelp, Siren, Buzzer
(Switchable)
Chime Section
Approx. 2~4 sec
Approx. 5~60 sec.(Variable)
Alert Section
Frequency
Output Level & Impedance
Sounding Time
Gong : Mixed Freq. Of 440Hz & 554Hz
2-tone : Ding-Dong
4-tone1 : DO-SOL-MI-DO
4-tone2 : DO-MI-SOL-DO
2-tone : 400Hz & 554Hz in Sequence
Yelp : 500Hz~750Hz
Siren : 400Hz~750Hz
Buzzer : 400Hz
+6dB/20kohm
Connections
Inputs : 4-pin & 3-pin Terminal Block
Output & Power : 32-pin DIN CON
Dimensions
40(W) x 172(H) x 275(D) mm
1.57(W) x 6.77(H) x 10.8(D) inch
Weight
420g / 0.92lbs
Finish
Dark Gray
Priority Oder
(1) Stop (2) Alert (3) Chime
Power Requirement
Current Consumption
NOR 113mA / MAX 135mA
18V DC
SPECIFICATION
(규격 및 성능)
ALERT
COM
EXT
CHIME
TIME
B.A
B.A
B.A
+8V
REGULATOR
+18V
+5V
G
V
V
SRART
STOP
COM
EXT
GROUP 1
GROUP 2
GROUP 3
GROUP 4
1
SRART
ALERT LEVEL
MS1
MS2
PGM 1
32-PIN DIN CON
PGM 2
PGM 3
PGM 4
CHIME S/W
CHIME BUSY
ALERT BUSY
PRI 1
PRI 2
PRI 3
PRI 4
2 TONE
YELP
SIREN
BUZZER
DO- MI-SOL-DO
DO-SOL- MI-DO
DING - DONG
GONG
B.A
B.A
CHIME LEVEL
THE SAME AS GROUP 1
DELAY
THE SAME AS GROUP 1
THE SAME AS GROUP 1
FIRST PRIORITY IN
GND
ODULES
M
CHIME & ALERT Signal Module
CA-42
BLOCK DIAGRAM
(블럭도)