24VDC
BATTERY
LINE
4 INPUT
LINE
5 INPUT
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
MIC 3 INPUT
MIC ON/OFF S/W
INFOR-
DESK
(
방송실
)
JPTT-10B
SCHOOL
MASTER
(
교장실
)
DIN CONNECTER
INPUT
JRC-10
JWP-500
3F
SCHOOL
PLAYGROUND
(
교 정
)
GYMNASIUM
(
운 동 장
)
2F
1F
SCHOOL
(
학교
)
For the priority of PTT Remote, please select "SLAVE/PRIORITY" S/W of JRR-10 (remote receiver) to "SLAVE"
본체의 REMOTE RECEIVER(JRR-10) SLAVE/PRIORITY S/W를 SLAVE로 선택하면 JPTT-10B이 최우선권이 부여됩니다.
CD PLAYER J6CD-10
TUNER JTU-110B
JWS 105
JWS 105
JWS 105
JCO-130
JCO-130
JWS 105
JWS 105
JWS 105
JWS 105
JWS 105
JWS 105
24VDC
CONNECT THIS TO TERMINAL OF FIRE RECEIVER CLOSED
RELAY FOR EMERGENCY.
(
비상시
화재
수신기의
릴레이
접점이
CLOSE
되는
단자와
연결
)
USE DIODE IN 4004 BETWEEN POWER REMOTE AND
FIRST PRIORITY MESSAGE.
(DIODE
는
IN 4004
사용
).
BATTERY
AUTOMATIC POWER SUPPLY AND AUTOMATIC ALERT VOICE M ESSAGE.
(
자동
전원공급
및
자동
메세지
경보방송
)
The above is for emergency situation like a fire.
First, record alert voice message to the memory
bank M6 in the JDM-10A(DIGITAL MESSAGE).
Second, select S/W MS802 PCB of JRR-10 to
"off" position so as not to operate E/M message
VIA JRC-10.
This is to prevent operating mistake from
remote controller(JRC-10).
이 방식은 기타 위급한 상황이 발생시 경고 방송을
하기 위한 수단입니다. 그리고 긴급 방송 녹음을
디지털 메세지 M6에 녹음 시키십시오.
긴급 방송 컨트롤이 REMOTE CONTROLLER(JRC-10)
에서 불가능하게 하기 위해 REMOTE RECEIVER
JRR-10의 PCB MS802를 "OFF"위치로 선택하십시오.
M1
M2
M3
BAND
TUNE
SCAN UP
M4
M5
M6
A PS
MUTE SEEK UP
STER
MONO
JTU-110B
AM/FM TUNER
STATION
CALL
POWER
TUNE
0
10
LEVEL
MODE
FUNCTION
STEREO
SIGNAL STRENGTH
888.8
888
8 8
6
5
4
3
2
1
J6CD-10
6CD CHANGER
MAIN POWER
LEVEL
OFF
ON
0
10
CD-POWER
ON/OFF
RESET
REPEAT
RANDOM
SCAN
PLAY/
PAUSE
STOP
DOWN
UP
DOWN
UP
POWER
EJECT
SENSOR
DISC
TRACK
9
MIC / LINE LEVEL
1
P.T.T
BASS
TREBLE
2
REMOTE
BASS
TREBLE
3
BASS
TREBLE
4
BASS
TREBLE
5
BASS
TREBLE
LINE LEVEL
1
6
2
5
3
4
SPK ZONES & ATT.
CLIP
0
3
8
13
CHIME
0
10
LEVEL
TEL
RINGER
LEAK
10
PAGING
10
ON
SIREN
0
10
LEVEL
OFF
LEAK
POWER
MASTER
AC
DC
TEMP
0
10
0
10
0
10
0
10
0
10
0
10
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
PROT
ATT. ZONE AMPLIFIER
JPA-1360B
OUTPUT LEVEL
ALL CALL
5
4
3
2
1
MIC/LINE
REC INPUT
H.P OUTPUT
CLIP MODE/CANCEL
UP
DOWN
SIG
REC LEVEL
0
10
LEVEL
0
10
ENTER
WEEKLY PROGRAM TIMER & DIGITAL MESSAGE
JTM-10
24V 30A
FUSE INSIDE
MASTER
AMP IN
PRE OUT
MIC
LINE
10
50
PHANTOM
POWER
3
GAIN
DC POWER
PHANTOM
POWER
2
PHANTOM
POWER
1
MIC
PRIORITY
PRIORITY
SLAVE
INPUT
DATA
LOW
IMP
4
3
2
1
5
NIGHT
RINGER
HOT
COLD
PAGING
IN
TEL
MESSAGE
FIRST
PRIORITY
ATT. OUTPUTS
SPK ZONES
P.A
REC
LINE IN
5
4
0dB
L
R
MIC / LINE INPUTS
REMOTE
AM
GND
POWER
L
R
MIC
LINE
10
50
GAIN
MIC
LINE
10
50
GAIN
DC 24V
MAX
0.2A
OUTPUT
DATA
PRIORITY
BUSY
G
AUDIO
17V
1 3 5 7
2 4 6 8
LINK
EACH ZONE 72W(MAX)
AC230V /50Hz1100W
300
FM 75
4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
SERIAL NO.:
Remote Receiver JRR-10
MODEL.: JPA-1360B
360W
ATT. ZONE AMPLIFIER
JPTT-10B REMOTE
P.T.T REMOTE
CHIME
AUDIO
24V
1 3 5 7
2 4 6 8
PRIORITY
GYMNASIUM
(
체육관
)
JWP-500
Summary of Contents for JPA-1120B
Page 1: ...ATT ZONE AMPLIFIER JPA 1120B JPA 1240B JPA 1360B JPA 1480B JPTT 10B JRC 10 JWP 500...
Page 5: ......
Page 6: ......
Page 16: ......
Page 20: ......