S
YSTEM CONNECTIONS
(시스템 연결 방법
)
3
EACH
24V/ 32A
EACH
24V/ 16A
DC OUTPUTS
BE SURE NOT TO EXCEED 24A OF DC OUTPUTS
FOR USING OF INTERNAL BATTERY.
T40AL 32V
T40AL 32V
T20AL 32V
T20AL 32V
T20AL 32V
CAUTION:
IN CASE OF USING EXTERNAL
BATTERY, INTERNAL BATTERY IS NOT AVAILABLE.
EXTERNAL
BATTERY
24V
CAUTION:
TO REDUCE THE RISK OF
FIRE REPLACE ONLY WITH SAME TYPE FUSE.
SERIAL NO.:
UNSWITCHED OUT
1
2
3
4
5
EMERGENCY POWER SUPPLY
MADE IN KOREA
MODEL NO.: JEP-352
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
24V
SWITCHED OUT
PWR CONTROL OUT
(FROM JPD-322A)
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
230V / 50Hz
MAX 105W
FUSE RATING
T2AH 250V
USE ONLY WITH A 250V FUSE
40
40
20
20
20
24V/1.5A
DC OUTPUT
24V/1.5A
SWITCHED TOTAL MAX OUTPUT 7000VA. SWITCHED EACH MAX OUTPUT 3500VA.
DC 24V
EQUIPMENT
ONLY.
DC 24V OUTPUT
230V / 50Hz
MODEL
NO.: JPD-322
A
POWER DISTRIBUT
O
R
MADE IN KORE
A
WARNING
:
TO
REDUCE THE RISK O
F
FIRE OR ELECTRIC SHOCK DO NOT EXPOS
E
THIS EQUIPMENT
TO
RAIN OR MOISTURE.
SERIAL
NO.
:
24V
(TO JRG-220A)
(TO JEP-352)
POWER OUTPUTS DELAY SOCKET(1 6) FOR POWER AMPLIFIERS.
SWITCHED IN
UNSWITCHED IN
PWR CONTROL IN
UNSWITCHED MAX 360VA
9
8
7
6
5
4
3
2
1
CAUTIO
N
RISK OF ELECTRIC SHOC
K
DO NOT OPE
N
MAIN
AC POWE
R
PRE AMP ONLY
BATTERY
G
E/M DATA
E/M
LINK
INPUT
G
FROM JSS-120A
TO RELAY BOX
UPPER JRG-220A
LOWER JRG-220A
FROM JPD-322A
AUDIO
IN
AUDIO
OUT
N.
O
CO
M
+24
V
OUT
EMERGENCY CARD
E/M
GN
D
G
DIRECT SPEAKER SELECTOR DATA IN
TELEPHONE PAGING CARD
TEL AUDIO IN
+5V OUT
10 9 8 7 6 5 4 3 2 1
20 19 18 17 16 15 14 13 12 11
3
3
3
2
1
3
4 CHANNEL P.A POWER AMPLIFIER
MADE IN KOREA
SERIAL NO.:
AC IN
50-60Hz
DC POWER
REMOTE
3-4
G
ROUTING
2-3
ROUTING
1-2
ROUTING
BALANCED 4dBu(1.23V) 30K
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
POWER
G
G
G
AMP
4
AMP
3
AMP
2
AMP
1
2
1
2
1
When you change IMP, you should put power switch off.
Then, loosen screw No. 1, 2, 3.At that time, you should
stop to pull it at the place you can see connector of IMP
change, otherwise, inner connector can be detached.
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
1
2
3
4
BALANCED OUTPUTS
RMS 240W X
1
3
2
BALANCED OUTPUTS
RMS 240W X 4
1
2
3
4
1
MODEL NO.: JPA-4240C
120VAC
F25AH 125V
220VAC
F12AH 250V
230VAC
F12AH 250V
240VAC
F12AH 250V
24V MAX 80A
MAX 2500W
G
LINK
INPUT
REMOTE AUDIO IN
REMOTE ZONE DATA OUT
AMP PRIORITY CONTROL OUT
REMOTE DATA
FROM JDR-104 / JRA-051A
FROM JSS-120A
REMOTE-1 CARD
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
1
,
2
BE SURE TO LINK
PER FOR DC POWER
2
1
2
1
2
1
DATA
ON
OFF
SLEEP MODE
400Hz
ON
OFF
PRE
POST
FUSE RATING T6.3A 250V
G
MONITOR
LINK
PREAMP
DC INPUT
INPUT
INPUT
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
MODEL : JMU-307B
MONITOR UNIT
24V 0.5A
12W
2
2
1
OUTPUTS
DC POWER
24VMAX 0.45A
MIC/LINE INPUTS
Line 10
Lef
t
Righ
t
P.T.T
REC
MIC INPUT
CHIME
G
3
4
5
6
7
8
9
10
1
120VAC
MAX 9.9W
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK DON'T EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
WARNING:
Chim
e
Remot
e
Line 9
Line 8
Line 7
MIC INPUTS
MADE IN KOREA
MODEL NO.: JMA-1410
1
4
3
52
7 6
2 1
3
PRIORITY
230VAC
220VAC
240VAC
GND
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Inside AC/DC Fuse
SERIAL NO.:
AC IN 50-60Hz
1
2
3
4
5
6
LED PWR
7
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3