Jedia JMU-307B Operating Instructions Manual Download Page 5

S

YSTEM CONNECTIONS 

(시스템 연결 방법

)

3

EACH

24V/ 32A 

EACH

24V/ 16A 

DC OUTPUTS

BE SURE NOT TO EXCEED 24A OF DC OUTPUTS 

FOR  USING OF INTERNAL BATTERY.

T40AL 32V

T40AL 32V

T20AL 32V

T20AL 32V

T20AL 32V

CAUTION:

IN CASE OF USING EXTERNAL

BATTERY, INTERNAL BATTERY IS NOT AVAILABLE.

EXTERNAL

BATTERY

24V

CAUTION:

TO REDUCE THE RISK OF

FIRE REPLACE ONLY WITH SAME TYPE FUSE.

SERIAL NO.:

UNSWITCHED OUT

1

2

3

4

5

EMERGENCY POWER SUPPLY

MADE IN KOREA

MODEL NO.: JEP-352

WARNING:

TO  REDUCE THE RISK OF  FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE. 

24V

SWITCHED OUT

PWR CONTROL OUT

(FROM JPD-322A)

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

230V    / 50Hz

MAX 105W

FUSE RATING

T2AH 250V

USE ONLY WITH A 250V FUSE

40

40

20

20

20

24V/1.5A

DC OUTPUT

24V/1.5A

SWITCHED TOTAL MAX OUTPUT 7000VA.  SWITCHED EACH MAX OUTPUT 3500VA. 

DC 24V

EQUIPMENT

ONLY.

DC 24V OUTPUT

230V    / 50Hz

MODEL

 NO.: JPD-322

A

POWER DISTRIBUT

O

R

MADE IN KORE

A

WARNING

:

TO

 REDUCE THE RISK O

F

FIRE OR ELECTRIC SHOCK DO NOT EXPOS

E

THIS EQUIPMENT

 TO

 RAIN OR MOISTURE.

 

SERIAL

 NO.

:

24V

(TO JRG-220A)

(TO JEP-352)

POWER OUTPUTS DELAY SOCKET(1   6) FOR POWER AMPLIFIERS.

SWITCHED IN

UNSWITCHED IN

PWR CONTROL IN

UNSWITCHED MAX 360VA

9

8

7

6

5

4

3

2

1

CAUTIO

N

RISK OF ELECTRIC SHOC

K

DO NOT OPE

N

MAIN

 AC POWE

R

PRE  AMP ONLY

BATTERY

G

E/M DATA

E/M

LINK

INPUT

G

FROM JSS-120A

TO RELAY BOX

UPPER JRG-220A

LOWER JRG-220A

FROM JPD-322A

AUDIO

IN

AUDIO

OUT

N.

O

CO

M

+24

V

OUT

EMERGENCY CARD

E/M

GN

D

G

DIRECT SPEAKER SELECTOR DATA IN

TELEPHONE PAGING CARD

TEL AUDIO IN

+5V OUT

10 9 8 7 6 5 4 3 2 1

20 19 18 17 16 15 14 13 12 11

3

3

3

2

1

3

4 CHANNEL P.A POWER AMPLIFIER

MADE IN KOREA

SERIAL NO.:

    AC IN

50-60Hz

DC POWER

REMOTE

3-4

G

ROUTING

2-3

ROUTING

1-2

ROUTING

BALANCED 4dBu(1.23V) 30K

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

POWER

G

G

G

AMP

4

AMP

3

AMP

2

AMP

1

2

1

2

1

When you change IMP, you should put power switch off.

Then, loosen screw No. 1, 2, 3.At that time, you should  

stop to pull it at the place you can see connector of IMP

change, otherwise, inner connector can be detached.

WARNING:

TO REDUCE THE RISK OF  FIRE

OR ELECTRIC SHOCK DO NOT EXPOSE THIS 

EQUIPMENT TO RAIN OR MOISTURE.

1

2

3

4

BALANCED OUTPUTS

RMS 240W X 

1

3

2

BALANCED OUTPUTS

RMS 240W X 4 

1

2

3

4

1

MODEL NO.: JPA-4240C

120VAC

F25AH 125V

220VAC

F12AH 250V

230VAC

F12AH 250V

240VAC

F12AH 250V

24V MAX 80A

MAX 2500W 

G

LINK

INPUT

REMOTE AUDIO IN 

REMOTE ZONE DATA OUT

AMP PRIORITY CONTROL OUT

REMOTE DATA

FROM JDR-104 / JRA-051A

FROM JSS-120A

REMOTE-1 CARD

20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

1

,

2

BE SURE TO LINK

PER    FOR DC POWER

2

1

2

1

2

1

DATA

ON

OFF

SLEEP MODE

400Hz

ON

OFF

PRE

POST

FUSE RATING T6.3A 250V

G

MONITOR

LINK

PREAMP

DC INPUT

INPUT

INPUT

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

MODEL : JMU-307B

MONITOR UNIT

  

24V 0.5A

12W

2

2

1

OUTPUTS

DC POWER

24VMAX 0.45A

MIC/LINE INPUTS

Line 10

Lef

t

Righ

t

P.T.T

REC

MIC INPUT

CHIME

G

3

4

5

6

7

8

9

10

1

120VAC

MAX 9.9W

TO REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK DON'T EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. 

WARNING:

Chim

e

Remot

e

Line 9

Line 8

Line 7

MIC INPUTS

MADE IN KOREA

MODEL NO.: JMA-1410

1

4

3

52

7 6

2 1

3

PRIORITY

230VAC

220VAC

240VAC

GND

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Inside AC/DC Fuse 

SERIAL NO.:

AC IN 50-60Hz

1

2

3

4

5

6

LED PWR

7

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3