IMPORTANT REMARKS

For any installation problem please contact our Customer Service
at the 39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00

V2 S.p.A. has the right to modify the product without
previous notice; it also declines any responsibility to
damage or injury to people or things caused by improper
use or wrong installation.

m

PLEASE READ THIS INSTRUCTION MANUAL VERY

CAREFULLY BEFORE INSTALLING AND PROGRAMMING
YOUR CONTROL UNIT.

• This instruction manual is only for qualified technicians, who

specialize in installations and automations.

• The contents of this instruction manual do not concern the

end user.

• Every programming and/or every maintenance service should

be done only by qualified technicians.

AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:

EN 60204-1

(Machinery safety. electrical equipment of 
machines, part 1: general rules) 

EN 12445

(Safe use of automated locking devices, test 
methods)

EN 12453

(Safe use of automated locking devices, 
requirements)

• The installer must provide for a device (es. magnetotermical

switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).

• Installation requires mechanical and electrical skills,

therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (Machine Directive 98/37/EEC, Annex IIA).

• The automated vehicular gates shall comply with the

following rules: EN 12453, EN 12445, EN 12978 as well as
any local rule in force.

• Also the automation upstream electric system shall comply

with the laws and rules in force and be carried out
workmanlike. V2 S.p.A. declines any responsibility in case of
automation upstream electric system not complying with the
laws and rules in force and not carried out workmanlike.

• The door thrust force adjustment shall be measured by

means of a proper tool and adjusted according to the max.
limits, which EN 12453 allows.

• The use of JEDI in dusty, saline or explosive environment

is forbidden

• The opener is designed for operation in dry rooms exclusively.

• For the safety and life of persons it is absolutely necessary to

follow all instructions.

• Keep these instructions save for later reference

• Do not permit children to play with the automated garage

door. Transmitters are to be kept safe and away from
children!

• Only operate the door if the entire door area is in your field of

view. Always be sure, that no persons or objects are located
within traveling range of the door.

• Do not use the opener when service or adjustment work is

required. A badly balanced door, or a faulty garage door
system may cause injuries.

• Please inform all persons using the door system on how to

operate it correctly and safely. Demonstrate and test the
reversion (with a 50 mm high obstacle at max. 150 N) as well
as the mechanical release.

• For the safety of persons and objects a safety check has to be

performed. Before finishing the initial operation make sure
that the drive stops and reverses according to the valid norms
(EN 12453) when hitting an obstacle (max. 150N force,
equivalent to approx. 15 kg, more than 50 mm above
ground).

• This test and measurement of force may only be performed by

a professional.
When hitting an obstacle the door has to stop and reverse
(completely or partially, depending on the setting of the PCB).
If the door does not run the correct path or if the door does
not reverse when hitting an obstacle the programming of
force and path has to be repeated.
Then please repeat the test.
If the door after the performed corrections does not stop and
reverse according to the valid norms, the door may not be
operated automatically.

• Check regularly that the gate reverse when detected a

40mm high obstacle

• Check often the automation, particularly the cables, springs

and mechanic parts for wear and tear, damages and
unbalancing

• The plug must be at easy reach, after the installation

• The data on the plate of the product are written on the label

put next to the connection terminal board

• Permanently mounted auxiliary devices (such as push buttons

etc.) should be mounted within view of the door.
The distance between moving parts and the height must be at
least 1.5 meters. It is essential that they are mounted out of
reach of children!

• Affix warning signs indicating the risk of being caught in the

door where they may be seen immediately or in the vicinity of
the permanently mounted push button.

Summary of Contents for JEDI-700

Page 1: ...IL n 321 EDIZ 01 11 2013 JEDI ELECTROMECHANICAL ACTUATOR FOR SPRING AND COUNTERWEIGHT BALANCED DOORS GB www remotecontrolgates co uk...

Page 2: ...Directive 2004 108 EC Radio Directive 99 05 EC Directive ROHS2 2011 65 EC The relevant technical documentation is available at the national authorities request after justifiable request to V2 S p A Co...

Page 3: ...or operation in dry rooms exclusively For the safety and life of persons it is absolutely necessary to follow all instructions Keep these instructions save for later reference Do not permit children t...

Page 4: ...easily without any friction The door must be properly balanced both before and after its automation stopping the door in any position it must not move carry out a balance weight adjustment if necessa...

Page 5: ...the connecting section bar R to the end position indicated by the two holes Q on the chain guide section bar 4 Adjust the tension of the chain using the Allen head screw with a 10 mm Allen wrench tur...

Page 6: ...actly half its height mark the reference points on the upper crossbeam and on the ceiling to facilitate positioning of the guide section bar 2 3 Fasten the bracket E to the upper crossbeam of the door...

Page 7: ...in the same plane If not add shims Connect the perforated bar L to the perforated bar of the arch arm using 2 6 x 15 bolts RELEASE OF THE AUTOMATION In order to release the automation from inside pul...

Page 8: ...The control panel inside JEDI is already cabled You just need to plug it in the electrical outlet to proceed with operational parameter programming To connect the photocells and the START button plea...

Page 9: ...nd then repeat the programming operation 1 Setting the open limit switch mPLEASE NOTE The open limit switch must be stored prior to the close limit switch If this procedure is used erroneously to set...

Page 10: ...parameters set press and hold the key for 5 seconds until the segments of the display illuminate one at a time until showing 0 mPLEASE NOTE if this parameter is modified then on completion of programm...

Page 11: ...enance alarm default 0 function deactivated If this function is activated the device emits BEEPs when the motor reaches 2000 operational cycles This alarm may be useful for scheduling maintenance oper...

Page 12: ...fter approx 1 second Release the key and press the remote control button twice the device emits a BEEP and the display is turned off to confirm memorising has been successful Press and hold key 0 appe...

Page 13: ...ENGLISH 24...

Reviews: