Pn Interval Days:
For: 0 (0~30)
Interval days - this sets the number of days between dosing -
it can be set in the range 0 -30. 0= dosing every day, 1 = dosing
every other day etc. Press
“↑”
“↓”
to increase or decrease the
number of days. Press
“
”
to enter dosing volume setting
Pn Dosing Volume:
Num: 1 -- 0010ml
Dosing Volume
:
The volume to be dosed. Press
“←”
“→”
to select the volume digit, press
“↑”
“↓”
to increase or decrease
(Max. setting is 9999ml). Press
“
”
to enter the first dosing time
setting. Num
“
1
”
means 1st dosing period.
Pn Dosing Time:
Num:1 -- 12:00
Dosing time set
:
Set the time the pump starts to dose.
Press
“←”
“→”
to choose the hour or minute. Press
“↑”
“↓”
to increase or decrease. Press
“
”
to enter the next dosing
period volume setting. Repeat until each dosing period is set.
Repeat for each pump. When finished setting all pumps, press
ESC“ to return to main menu.
Warning
1, For indoor use only. Avoid contact with moisture and humidity.
2, Do not use with corrosive liquids or liquids that can easily crystallise.
3, Before use, please prime the tubing with liquid via manual mode, and calibrate
the flow rate of each pump.
4, Do not disassemble the product.
Assembling drawing
Press and pull the click
strongly when disassemble
the grey card
Loose the four
click,dispart the
above & under
cover slightly
Press the lock click
strongly when disassemble
Replace the rubber
hose,Make sure the
position and tightness
of the hose please