Turn on the power , more than 25 seconds no touch control button, the LED to micro 
bright, the controller enter the screen saver mode; the led return to normal When press 
any button. 
 

Five, Date memory function 

 
Memory function, ensure that the pump rework upon keeping the same parameter. 
 

Six, Fault code and description 

The fault code abnormal and flashing when the controller abnormal work, the code 
explanation is as below: 
 

Er01:

 Abnormal Working current

;

 Check if the pump short of voltage or the controller 

broken 

Er02:

 Controller overheating; Check whether the controller exposed to the sunshine or 

in high temperature environment 

Er03:

 Pump idling

;

 Check the pump work dry 

Er04:

 The impeller stops running; Check if the pump short of voltage or the controller 

broken 

Er05:

 Abnormal Working voltage. Check the input supplying voltage 

 

Note:  for  indoor  use,  the  power  socket  must  be  installed  with  the  leakage  current 

protecting device, and the leakage current shall not exceed 30mA (please the consumer 
to install the leaking current protection device by themselves). 
 

Performance Parameters Table 

No: 

Model    No: 

Voltage 

Control box (W) 

Consumption 

(W) 

Flow    rate 

(L/H) 

Head Max (M) 

DCP-2500 

DC 24V 

DCP-2500 

23 

2500 

2.5 

DCP-3000 

DC 24V 

DCP-3000 

25 

3000 

3.0 

DCP-4000 

DC 24V 

DCP-4000 

32 

4000 

4.0 

DCP-5000 

DC 24V 

DCP-5000 

40 

5000 

4.0 

DCP-6500 

DC 24V 

DCP-6500 

55 

6500 

4.5 

DCP-8000 

DC 24V 

DCP-8000 

65 

8000 

5.2 

DCP-10000 

DC 24V 

DCP-10000 

80 

10000 

6.0 

DCP-15000 

DC 24V 

DCP-15000 

105 

15500 

7.0 

DCP-18000

 

DC 36V 

DCP-18000

 

130 

18000 

10 

DCP-20000

 

DC 36V 

DCP-20000

 

165 

20000 

9.5 

 
 

WARNING 
 

l

 

Do not connect to any other power supply over the rated voltage   

l

 

Do not put the pump in the flammable liquid. 

l

 

Do not use the pump in the water temperature above 35 . 

l

 

Maximum water depth 1.5M 

l

 

Maximum head Max please see the parameter table.

 

l

 

Do not immerse the plug into water or other liquid. 

l

 

This appliance is not allowed to use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety. 

l

 

Children should be supervised to ensure that they do not play with the 
appliance.

 

l

 

This appliance can be used by children aged from 8 years and above and 
persons with reduced physical, sensory or mental capabilities or lack of 
experience and knowledge if they have been given supervision or instruction 
concerning use of the appliance in a safe way and understand the hazards 
involved.

 

 

CAUTION 
 

Always disconnect the pump from the power supply before cleaning, maintenance and 
handling. 
 
Do not let the pump work dry. 
Do not lift the pump by holding the power cord only 
Do not use the pump in the heating liquid. 
The pump suitable for both fresh water and sea water   
The  pump  can  used  as  submersible  pump  and  used  as  non-submersible,  pump  house 
must be filled with water. 
The pump can not run in the swimming pool. 
Automatic shut off if no water for 2 minutes. 
Pull the plug out, and re-insert for resuming work 
 

Operation 
 

A clogged or dirty intake screen will reduce the performance. 
If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris 
contacting the intake. If the flow is low, please adjust the regulator on the sealing cover. 
 
Do  not  let  the  pump  run  in  dry.  The  pump  will  be  broken  easily.  Normally,  put  the 
pump  into  water,  plug  on.  At  the  beginning,  it  probably  can’t  pump  water,  because 

Reviews: