1
3
7
/1
4
0
1
8
INLET CONTROL VALVE
99ICV Series
INSTALLATION INSTRUCTIONS
11/04
69482 Rev. B
SAVE THESE INSTRUCTIONS
CAUTION:
The vessel manufacturer must comply with the
requirements of CFR 40 1060.202. Any questions can be
directed to www.attwoodmarine.com
Failure to follow these instructions may result in accidental
fuel system over-pressurization. Users must follow these
instructions to ensure vessel function and operation
EMISSION-RELATED INSTALLATION INSTRUCTIONS
Failing to follow these instructions when installing the Attwood
Inlet Control Valves in a piece of nonroad equipment violates federal law
(40 CFR 1068.105(b)), subject to fines or other penalties as described in
the Clean Air Act.
FEATURES:
Attwood’s Inlet Control Valve allows proper fuel flow into the fuel tank during refueling.
As the fuel tank reaches full liquid capacity, the Inlet Control Valve works in conjunction
with the Fill Limit Vent Valve to ensure no spitback/wellback and automatic nozzle
shutoff. The Inlet Control Valve also prevents fuel from draining into fill hose/deckfill
area during vessel operation and trailering. The Inlet Control Valve includes features to
allow vapor and liquid to pass the valve in order to ensure the system does not become
accidentally over pressurized.
REQUIRED FOR INSTALLATION
t
1-1/2" (38mm) I.D. Fill Hose
t
(4) Hose Clamps, 1-1/2
"
(38mm), trade size 028, 300-grade all-stainless
(both band and screw)
t
5/16" (8mm) Nut Driver or Medium Flathead Screwdriver for hose clamp installation
t
Torque Monitoring Device to ensure proper torque level for all fasteners
INSTALLATION INSTRUCTIONS
1. Ensure that the 1-1/2" (38mm) hose has a clean, perpendicular cut before Inlet
Control Valve installation. Loosely install two (2) all-stainless, 1-1/2
"
(38mm)
wide, trade size 028 hose clamps over hose. (Figure 1)
2. Install Inlet Control Valve with “
FLOW
” and arrow pointing towards the Fuel Tank
and “
TOP
” identification facing up in horizontal or angled applications. This
orientation is not required in complete vertical applications. Ensure that the hose
is fully inserted, bottoming the end on the chamfer of the Inlet Control Valve.
3. Place and fasten hose clamp 1/4" (6mm) from hose end. Fasten to 36 +/- 4 in-lbs.
Do not overtorque.
4. Place and fasten hose clamp adjacent to first hose clamp. Fasten to 36 +/- 4 in-lbs.
Do not overtorque.
5. Inspect second hose to install onto inlet side of Inlet Control Valve, ensuring a
clean, perpendicular cut. Loosely install two (2) hose clamps over hose and install
hose onto Inlet Control Valve, bottoming the end of hose at the base of the Inlet
Control Valve inlet.
6. Place and fasten hose clamp 1/4" (6mm) from hose end. Fasten to 36 +/- 4 in-lbs.
Do not overtorque.
7. Place and fasten hose clamp adjacent to first hose clamp. Fasten to 36 +/- 4 in-lbs.
Do not overtorque.
8. If the Inlet Control Valve is installed in the engine compartment, a heat shield
(99ICV000HS1) is required. Please reference separate instruction sheet for heat
shield installation.
NOTES:
t
Trade Size 028 (1-1/4" min., 2-1/4" max. dia.), 1-1/2
"
(38mm) wide
t
1/2" (13mm) stainless steel band, housing and 5/16" (8mm) hex screw
t
Inspect screw torque annually
t
Do not step on Valves
t
1/2" (13mm) Clearance required around component
t
Not intended for siphoning through Inlet Control Valve under any circumstances
LOCATION
t
Install anywhere between the Deck Fill and tank. A minimum of 6
"
(15.2cm) is required
between the Deck Fill and Inlet Control Valve.
t
Must be installed in a readily accessible location
t
Fill hose must be self draining between Deck Fill and Inlet Control Valve for all expected
boat conditions.
t
Fill hose must be self draining between Inlet Control Valve and tank for all expected
boat condition.
Important safety instructions
(for all Attwood 99FL/99GV/99CC/99ICV/99DF components):
When a fuel system is configured with Attwood 99FL and/or 99GV Series Vent Valves, the
following safety precautions must be taken;
1. Use only an Attwood 99ICV series Inlet Control Valve in-line with the Fuel Fill Hose. No
other fill hose valves should be installed in order to ensure the safety of the fuel system
and vessel. The Attwood 99ICV series inlet control valves include features to allow
vapor and liquid fuel to pass the valve in order to ensure the inlet valve does not create
an accidentally sealed fuel tank/system.
2. Use only an Attwood 99DF series Deckfill. The Attwood 99DF series Deckfill includes
overpressure relief safety valves that allow unintended pressure to be released in the
event that the tank becomes accidentally overfilled and/or over pressurized.
MANUFACTURER REQUIREMENTS
The information below applies only to EPA CFR 40 1060.135. The vessel manufacturer
is responsible to meet all additional regulatory labeling requirements including EPA,
CARB, USCG and others as necessary. The below information is for reference only.
The vessel manufacturer should refer to CFR 40 for complete labeling guidelines.
In order to meet the requirements of CFR 40 1060.135, the vessel must be labeled
with respect to evaporative emissions in the following manner when installing certified
components;
Excerpt from CFR 40 1060.135
(a) You must affix a permanent and legible label identifying each engine or piece of equipment before
introducing it into U.S. commerce. The label must be—
(1) Attached in one piece so it is not removable without being destroyed or defaced.
(2) Secured to a part of the engine or equipment needed for normal operation and not normally
requiring replacement.
(3) Durable and readable for the equipment’s entire life.
(4) Written in English.
(5) Readily visible in the final installation. It may be under a hinged door or other readily opened
cover. It may not be hidden by any cover attached with screws or any similar designs. Labels on
marine vessels must be visible from the helm.
(c) If you produce equipment without certifying with respect to evaporative emissions, the equipment
label specified in paragraph (a) of this section must—
(1) State: ‘‘MEETS U.S. EPA EVAP STANDARDS USING CERTIFIED COMPONENTS.’’
(2) Include your corporate name.
Below is an example of a label specified by CFR40 1060.135 for use with certified
components;
MEETS U.S. EPA EVAP STANDARDS USING
CERTIFIED COMPONENTS
CORPORATE NAME
Please refer to CFR 40 1060.135 to review EPA vessel labeling requirements.
The NMMA has a program to supply OEM builders with labels. Please refer to the NMMA
website below for further information regarding the NMMA label program;
www.nmma.org/certification/products/labelsanddecals.aspx
A.B.Y.C.
American Boat & Yacht Council
3069 Solomon’s Island Road
Edgewater, Maryland 21037
www.abycinc.org
U.S. Coast Guard
Washington, DC 20460
www.uscgboating.org
E.P.A.
401 “M” Street, SW
Washington, DC 20593 www.
www.epa.gov
ISO
iso.org
National Marine
Manufacturers Association
(NMMA)
231 S. LaSalle Street
Suite 2050
Chicago, IL 60604
www.NMMA.org
FIGURE 2
Full Carbon Canister System
Inlet Control
Valve
FIGURE 1
Fill Hose
1.5" (38mm) I.D.
not included
Valve
Assembly
Fill Hose
1.5" (38mm) I.D.
not included
1/4"
6mm
1/4"
6mm
©2011 Attwood Corporation
1016 North Monroe Lowell, MI 49331
www.attwoodmarine.com
To Deck Fill
To Tank
Hose Clamps
Trade Size 028,
300-Grade Stainless Steel
not included
TWO-YEAR WARRANTY & LIABILITY
Generally:
Attwood Inlet Control Valves are covered by a two (2) year limited warranty
from the date of a Vessel’s first retail sale.
Pre-requisites to Warranty Eligibility:
For the warranty coverage described herein to
apply, the following conditions must be met:
t
Component must have been properly installed per Attwood installation instructions; and
t
The component cannot have been altered or abused by Boat Company or its customers.
Warranty Terms for Components:
Attwood warrants that any Attwood Inlet Control Valves are free from defects in materials
and workmanship and are designed, built, and equipped to conform at the time of sale
to Boat Company with the 40CFR.1060 requirements. For two (2) years from the date
of a Program Boat’s first retail sale, Attwood will, at its sole option, repair or replace any
components that fail due to a defect in material or workmanship. ATTWOOD PROVIDES NO
WARRANTIES WITH RESPECT TO ANY PART OR COMPONENT NOT MANUFACTURED BY
ATTWOOD, INCLUDING FUEL TANKS. Boat Company is responsible for the installation of
all Systems, whether installed by Boat Company or under its direction.
APPENDIXES
Summary of Contents for MERRY FISHER 855
Page 1: ...MERRY FISHER 855 Marlin OWNER S MANUAL 959207 Index C...
Page 2: ......
Page 6: ...6 140 16 5 WINTER STORAGE 131 16 6 TRANSPORT 132 17 ENVIRONMENT 133 18 APPENDIXES 135...
Page 10: ......
Page 16: ......
Page 24: ...24 140 4 1 2 Windscreen washer Reservoir location Saloon Control Steering station...
Page 44: ......
Page 61: ...61 140 7 3 2 Diagram of the layout AC circuit 7 12V 12V 12V 1 3 4 5 2 2 7 8 6 AC SYSTEM...
Page 64: ......
Page 66: ...66 140 Gas cylinder locker Cooker open Closed Supply valve Gas Access Forward cabin...
Page 70: ...70 140 Location Saloon Capacity 42 litre...
Page 104: ...104 140 Reference Designation 1 Mechanical actuator 2 Control panel 3 Control box 4 Fuse...
Page 106: ......
Page 114: ......
Page 117: ...117 140 Fish case Fishpond Seating Cockpit Must be secured while sailing 14 DECK FITTINGS...
Page 126: ......
Page 134: ......
Page 138: ...138 140...
Page 139: ...139 140 18 APPENDIXES...
Page 140: ......