Chapter 8
Copper Testing
Measuring opens
OneExpert DSL User’s Guide
66
22052280, Revision 001
April 2014
A warning appears during the stress pulse to indicate higher voltage is present.
7
To adjust the
Gain
or
Pulse Width
, either drag the line across the bar or touch the + or - key
to adjust it.
Pulse Width only appears when
Pulse Width
is selected on the Options pop-up menu (from
the
Options
system key).
8
To help identify small or distant faults, use the up or down arrow keys to gain the vertical axis
and enhance the reflection of faults. Do not apply excessive gain. This makes a normal condi-
tion appear as a fault.
9
If you want a larger image, you can rotate the screen to Landscape by selecting the
Trace
system key and then select
Landscape
.
10
Using the Peak Hold mode, the OneExpert DSL DSL can display minimum, maximum, and
current TDR traces over a test period. This feature is useful for analyzing faults that occur
intermittently. To enable Peak Hold mode, select the
Options
system key and then select
Peak Hold
.
11
To save the results to a report, use the Tray menu (
12
You can also view and compare current and saved TDR traces using the Results key. For
information on saving your results in graphical form, see
.
13
To learn what your results mean, see
.
Locating cable faults with the TDR is complete.
Measuring opens
The opens feature measures the total electrical (capacitive) length of a pair.
To measure opens
1
Connect the Tip (A), Ring (B), and Ground (Earth) leads to the line under test.
2
From the Copper menu, touch the
Opens
button.
3
For greatest accuracy, JDSU recommends that you compensate the opens measurement to
remove the effects of the test leads. To compensate the opens measurements
a
Swipe downward on the screen to access the Tray menu.
b
Select the
OPENS Compensation
system key
c
Follow the instructions on the screen to connect the black, red, and green leads to
perform test lead compensation.
d
Touch
Compensate
.
The compensation stops automatically when finished.
4
Press the
Home
navigation key to return to the Opens menu.
Summary of Contents for OneExpert DSL