Appendix A Test Results
Error Stats results
300
HST-3000 Ethernet Testing User’s Guide
Error Stats results
The Error Stats category lists error statistics such as the
number of FCS errored frames, runts, and out of sequence
(Oos) frames. Results in this category accumulate after you
transmit traffic over the link.
describes the results
that appear in the Error Stats category.
Remote Fault
If supported by the Ethernet link part-
ner, indicates a reason for auto-negoti-
ation failure. If auto-negotiation
succeeded, the result will read “NO”.
Table 36
Optical Auto-Neg Stats test results (Continued)
Result
Description
Table 37
Error Stats test results
Result
Description
Acterna Payload
Errors
A count of received IP packets contain-
ing Acterna Payload checksum errors.
NOTE: This result only appears if you
receive an Acterna payload, and there
are payload errors in the received data
stream.
Code Violation Rate
The ratio of code violations to bits
received since the last test restart.
Code Violation Sec-
onds
A count of the number of seconds dur-
ing which code violations occurred.
Code Violations
A count of invalid 10-bit code words in
the bit stream.
Errored Frames
A count of FCS errored frames, runts,
and jabbers.
Summary of Contents for IP Video Test Option HST-3000
Page 1: ...HST 3000 Ethernet Testing User s Guide ...
Page 2: ......
Page 22: ...About This Guide Conventions xx HST 3000 Ethernet Testing User s Guide ...
Page 138: ...Chapter 3 Ethernet Testing MAC in MAC testing 116 HST 3000 Ethernet Testing User s Guide ...
Page 202: ...Chapter 5 TCP UDP Testing Loopback testing 180 HST 3000 Ethernet Testing User s Guide ...
Page 278: ...Chapter 9 Troubleshooting Resolving problems 256 HST 3000 Ethernet Testing User s Guide ...
Page 346: ...Glossary 324 HST 3000 Ethernet Testing User s Guide ...
Page 354: ...Index 332 HST 3000 Ethernet Testing User s Guide ...
Page 355: ......