Chapter 9 Troubleshooting
Resolving problems
250
HST-3000 Ethernet Testing User’s Guide
Resolving problems
describes situations that you may encounter when
using the HST-3000.
Table 14
Problems and resolutions
Problem
Description
Resolution
Link is not active
After specifying link initializa-
tion settings and connecting
the HST to the circuit, the
Link Active status is No.
Verify the following:
–
The HST on the on the
far end is connected to
the circuit.
–
The HST and it’s link
partner are configured
for the same rate of traf-
fic.
–
The HST and it’s link
partner both have auto-
negotiation turned ON,
and share at least one
common capability, or
both have auto-negotia-
tion turned OFF.
If you are testing 10/100/1G
electrical Ethernet:
–
Verify that the RJ-45
jacks on the left of the
Ethernet SIM were used
to connect to the circuit.
The RJ-45 jack on the
top of the base unit is
only used for Ethernet
TE, VoIP, and IP Video
testing.
If you are testing 1G or
100M optical Ethernet:
–
Verify that you turned the
laser on using the
Laser On action key.
Summary of Contents for IP Video Test Option HST-3000
Page 1: ...HST 3000 Ethernet Testing User s Guide ...
Page 2: ......
Page 22: ...About This Guide Conventions xx HST 3000 Ethernet Testing User s Guide ...
Page 138: ...Chapter 3 Ethernet Testing MAC in MAC testing 116 HST 3000 Ethernet Testing User s Guide ...
Page 202: ...Chapter 5 TCP UDP Testing Loopback testing 180 HST 3000 Ethernet Testing User s Guide ...
Page 278: ...Chapter 9 Troubleshooting Resolving problems 256 HST 3000 Ethernet Testing User s Guide ...
Page 346: ...Glossary 324 HST 3000 Ethernet Testing User s Guide ...
Page 354: ...Index 332 HST 3000 Ethernet Testing User s Guide ...
Page 355: ......