2.2  Verify Local Connection to Session Border Controller (SBC) 

 

Step 

Action 

Details 

1.

 

Connect 

Connect to the Ethernet port on Session Border Controller (SBC) using a 
straight through Ethernet cable and the RJ-45 connector labeled 

ETHERNET

 on the top of the mainframe.   

 

 

2.

 

View Results 

Press the 

Home 

key to display VoIP Phone Results.   

 

3.

 

Check LED 

Green

 Sync LED indicates the HST-3000 has connected to the SBC, 

and the Ethernet link is active. 

             

 

 
If the 

Sync 

LED is not green, verify the following: 

 

The HST-3000 is configured correctly, as outlined above. 

 

The SBC LAN port  is enabled and configured for the correct speed 
and duplex (auto negotiate or fixed speed/duplex) 

 

Cables are good quality and properly connected. 

 

If the 

Sync 

LED is still not green, the HST-3000 cannot establish an 

Ethernet link with the SBC.  Contact VoIP Technical Support. 
 

4.

 

Test 

For Registering Trunks, proceed to Section 2.3.  For Non-Registering 
Trunks, proceed to Section 2.4. 
 
 

 

 

Technical Support 

[email protected]

 

866-228-3762 

 

 

 

 

Summary of Contents for IP Video Test Option HST-3000

Page 1: ...Page 1 of 14 JDSU HST 3000 SIP Trunk Testing Guide Version 1 1 May 4 2013 Technical Assistance Center tac jdsu com 855 ASK JDSU...

Page 2: ...t isolation and troubleshooting using the JDSU HST 3000 portable business services tester Revision History Revision Description Name 1 0 Initial Draft Dave Baker JDSU 1 1 Added network diagram Dave Ba...

Page 3: ...made from the HST 3000 front panel by using the keypad to select the option number or by using the arrow keys to scroll to the desired selection and pressing the OK key HST 3000 Front Panel Power Key...

Page 4: ...deo Phone Step Action Details 1 Power On Press the green Power Key to turn on the HST 3000 2 Launch Test App Press the ETH TE Soft key Press the OK key to launch the Ethernet TE test application 3 Loa...

Page 5: ...e Terminate CC Standard SIP Alias See Work Order For Registering Trunks enter Phone Number for the PBX For Non Registering Trunks enter as follows Phone SBC LAN IP Address user phone i e 8608635180 16...

Page 6: ...s connected to the SBC and the Ethernet link is active If the Sync LED is not green verify the following The HST 3000 is configured correctly as outlined above The SBC LAN port is enabled and configur...

Page 7: ...Successful indicates that the HST 3000 is registered with the Proxy Server 2 Troubleshoot If Proxy Registration Successful is not displayed in the Message Bar or Messages Log verify the following The...

Page 8: ...the call to ring at least 2 times Confirm the Ring back tone is heard on your cell phone and press the OK key to answer to call 3 Converse Confirm that Voice is heard and Voice Quality is good on the...

Page 9: ...e to enter 2 OK Press OK again to go off hook and place the call The HST 3000 will send an INVITE message to set up the call Call status is displayed in the VoIP Phone results screen 3 Answer Answer t...

Page 10: ...sure scores are good as indicated by a green checkmark If RTCP is disabled in the network Remote Scores will be unavailable If the Delay Jitter Loss or Overall Score indicate that any tests failed con...

Page 11: ...dd Enter a name alias and IP Address at the prompts For Registering trunks enter the phone number at the Alias prompt For non registering trunks enter a URI at the Alias prompt as follows Phone Number...

Page 12: ...derground public utility location 911 emergency services 3 Dial Using the HST 3000 Speed soft key select the first entry in the dial plan and press OK Press OK again to dial The HST 3000 sends an INVI...

Page 13: ...ct the USB Flash Drive to the HST 3000 s USB port on the top of the mainframe 3 System Tools Press the System Navigation key and press the TOOLS soft key Press the OK key to launch the File Manager 4...

Page 14: ...ss the Configure Navigation key Press the Right Arrow key several times to display the Config Store menu select New Config enter a Filename at the prompt and press OK 2 Shutdown Press the green power...

Reviews: