JDS Labs Model # C5D v1.01 | Instructions Rev. 2, December 2013
Pg. 2 of 2
Charging
C5D uses smart Li-Ion recharging technology, with typical charge time of 2-4
hours. Connect a mini-USB cable from any computer or USB power adapter and
set charge switch to
CHG
position to begin charging.
C5D may be used while charging, and USB cord may be connected or
disconnected as desired.
Set charge switch to
BAT
position when listening via USB from a phone or tablet. BAT position disables
charging so that C5D consumes no power from your device.
Amplifier Specifications
Frequency Response
+/- 0.1 dB
THD+N (20-
20kHz, 150 Ω)
0.0015%
THD+N (20-
20kHz, 32 Ω)
0.0045%
Noise
-105 dBu
Crosstalk @ 150
Ω
-67 dB
Inter-channel Phase @ 1kHz
+/- 0.01 degrees
Channel Balance
+/- 0.55 dB
Max Output @ 600Ω
4.146 VRMS
Max Output @ 150Ω
3.580 VRMS
Max Output @ 32
Ω
1.182 VRMS
Power Supply
14.0 Vpp
Output Impedance
0.62
Ω
Battery Run Time
6-8 Hours*
Charge Time
2-4 Hours
Operating Temp
0°C to 60°C
Operating Humidity
0 to 85% Relative
Dimensions
99.5 x 61.5 x 14.0 mm
Weight
4.2 ounces
Test equipment: PrismSound dScope Series III audio analyzer, Tektronix TDS1012 oscilloscope
*Run time observed using amplifier and DAC in self-power mode. Actual run time varies with equipment and volume.
ATTENTION:
Battery must only be replaced with equivalent 3.7V, 1200mAh Li-Ion pack. Misuse of
the battery may cause fire or burns. JDS Labs, Inc. is not responsible for damages caused by
device misuse, or failure to adhere to device instructions.
FCC Certifications
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
CE Mark Warning
This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the essential protection requirement of Council Directive 89/336/EEC on
the approximation of the laws of the Member States relating to electromagnetic compatibility.
Amplifier
LED Status
Off
Off
On
Solid Green
Low Battery Flashing Green
Charging
Blue
DAC Specifications
Frequency Response
+/- 0.14 dB
THD+N 100Hz
0.0014%
THD+N 20Hz
0.0015%
THD+N 10kHz
0.0025%
IMD 19/20kHz, -7dBFS
0.0015%
Noise, A-Weighted
-103 dBu
Dynamic Range
> 109 dB A-Weighted
Linearity Error, -90dBFS 24/96 0.2 dB
Crosstalk -10dBFS
-80 dB
USB Jitter, Marked Sum
-112 dB
Maximum Output
2.0 VRMS