7

제품 출고 당시 제품 외부에서 조정이 불가능한 내부 PRIORITY기능은 다음과 
같이 선택되어 있습니다.
팩신호 PRIORITY 스위치(전면PCB SW305) : SLAVE(PRIORITY당함)선택.
아래 표기된 내용은 시스템의 모든 신호 입력에 대한 PRIORITY 순위별로 작성
하였으며 PRIORITY신호 컨트롤은 자동으로 차단 및 회복됩니다.

When shipped it is factory preset as follows pack signal priority switch
(FRONT PCB SW305) : Setting at SLAVE.
The following is priority ranking against all signal inputs of system and priority
signal is "NO" "OFF" automatically.

PRIORITY FUNCTION

PRIORITY 기능

SIGNAL OUTPUTS

CONDITION

REMARKS

PRIORITY
RANKING

1

2

3

4

5

DIGITAL MESSAGE
(DM-100)
M6 ALERT VOICE 
MESSAGE

-Rear apnel No.

 message first priority

 S/W :"ON"(close) SELECTOR.
-Pack signal priority S/W(SW305):
  PRIORITY

All signals closed.
Announcement only for M6
(alertvoice message)

PT.T. MIC & remote control mic 
activated

Chime/siren, ringer, line4,5 pack
signalsnot activated.

Ringer, line4, 5 pack signal not
activated.

Output only for P.T.T MIC and pack
(TP-100,CDP-100,CDR-100,
 DM-100) others will be closed.

-Rear panel No.

 

 MIC PRIORITY S/W :"ON"
-Pack signal priority S/W(SW305):
 SLAVE

-Rear panel No.

 

 MIC PRIORITY S/W :"OFF"
-Pack signal priority S/W(SW305):
 SLAVE

-Pack signal priority S/W(SW305):PRIORITY
-Rear panel No.

 remote receiver(RR-100)

 side S/W : SLAVE
-Side S/W ontne rear of remote control : 
 SLAVE

-Rear panel No.

 remote receiver(RR-100)

 side S/W : PRIORITY

P.T.T MIC

P.T.T MIC
REMOTE CONTROL
MIC

MIC 1, 2, 3
TEL PAGING

MIC 1, 2, 3
CHIME/SIREN

신 호 출 력

비        고

PRIORITY
순        위

1

2

3

4

5

DIGITAL MESSAGE
(DM-100)
M6 비상 경고 방송

-후면 판넬 ⑩번 Message first priority
  스위치 :"ON"(close) 선택 
-팩 신호 PRIORITY 스위치(SW305):
  PRIORITY선택

모든 방송이 차단되고 M6의 녹음 
방송만 출력.

P.T.T 마이크와 remote control mic
동시 방송됨.

Chime/siren, ringer, 라인 4, 5 각종 
팩 신호 차단.

Ringer, 라인4, 5 각종 팩 신호 차단.

P.T.T 마이크 신호 및 팩류 (TP-100,
CDP-100, CDR-100, DM-100)
신호만 출력기타, 모든 방송중단.

-후면 판넬 ①번 MIC PRIORITY 
  스위치 : "ON" 선택.
-팩 신호 Priority 스위치(SW305) :
  SLAVE 선택

-후면 판넬 ①번 MIC PRIORITY 
  스위치 : "OFF" 선택.
-팩 신호 Priority 스위치(SW305) :
  SLAVE 선택

-팩 신호 PRIORITY 스위치(SW305):PRIORITY
-후면 판넬 ⑭번 Remote receiver(RR-100)
  슬라이드 스위치 : SLAVE 선택.
-리모트 콘트롤 후면 슬라이드 스위치:
  SLAVE 선택

-후면 판넬⑭번 Remote Receiver(RR-100)
  슬라이드 S/W : PRIORITY선택

P.T.T MIC
팩 신호.

P.T.T MIC
REMOTE CONTROL
마이크

MIC 1, 2, 3
TEL 페이징

MIC 1, 2, 3
CHIME/SIREN

조       건

LINE 4,5 TEL ringer, tuner(TP-100) have no priority against other signals.
Also they can not be activated priority function VIA pack signal priority 
S/W "SLAVE"

LINE 4, 5 RINGER, 튜너(TP-100) 신호는 다른 모든 신호에 대해 
우선권이 없습니다.
단, 팩신호 PRIORITY S/W를 SLAVE위치에 선택시만 팩 시리즈의 우선권이 
상실됩니다.

P

RIORITY FUNCTION

 

(우선권 기능)

Summary of Contents for ZA-1120A

Page 1: ...ATT ZONE AMPLIFIER ZA 1120A ZA 1240A WWW JD MEDIA CO KR JD MEDIA...

Page 2: ...P 0 3 8 13 CHIME 0 10 LEVEL TEL RINGER LEAK 10 PAGING 10 ON SIREN 0 10 LEVEL OFF LEAK POWER MASTER AC DC TEMP 0 10 0 10 0 10 0 10 0 10 0 10 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 PROT ATT ZON...

Page 3: ...Keep in mind the following when connecting the apparatus Connect the apparatus after reading of O P manuals Connect each connection of amplifier perfectly if not it maybe Caused hum damage electric s...

Page 4: ...cabinet IMPORTANT Be sure rear of amplifier is securely mounted to rack AMPLIFIER TOP VIEW 4in 10cm MIN RACK CABINET 2 4in 6cm MIN RACK MOUNT SPACE AIR FLOW IN RACK CABINET AIR FLOW EQUIPMENT RACK SID...

Page 5: ...EN TP 100 DM 100 CDP 100 CDR 100 PACK OPTION DELAT RJ45 1 DEGITAL MESSAGE 2 CHIME 3 REMOTE CONTROLLER RC 100 3 DEGITAL MESSAGE DM 100 MESSAGE FIRST PRIORITY MIC 1 2 3 1 MIC LINE LEVEL 1 MIC LINE LEVEL...

Page 6: ...g is activated priority makes stopping all signal like LINE 4 5 CHIME SIREN and signal of modules against paging set switch of SW305 on the FRONT PCB to SLAVE If priority is not activated against MIC...

Page 7: ...alanced jack The stereo signal of the connected sound sources gets internally converted into a manual signal All signals can be recorded but recording out can not be adjusted by master volume because...

Page 8: ...ration of data of data receipt data LED indicator will be turn ON DATA LED INDICATOR SLAVE SELECTOR All signal output of remote controller RC 100 will be closed under setting on of priority switch on...

Page 9: ...signal priority S W SW305 SLAVE Rear panel No MIC PRIORITY S W OFF Pack signal priority S W SW305 SLAVE Pack signal priority S W SW305 PRIORITY Rear panel No remote receiver RR 100 side S W SLAVE Sid...

Page 10: ...roller RC 100 SECRETARY SUPER INTENDENT 24VDC BATTERY MANUFACTURING AREA OR SHOP CD PLAYER 6CD 100 LINE 4 INPUT LINE 5 INPUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 REC LEVEL EXEC 0 10 H P MIC LINE IN CLIP...

Page 11: ...0 50 PHANTOM POWER 3 GAIN DC POWER PHANTOM POWER 2 PHANTOM POWER 1 P T T REMOTE MIC PRIORITY AUDIO IN CHIME PRIORITY G PRIORITY SLAVE INPUT DATA LOW IMP 4 3 2 1 5 NIGHT RINGER HOT COLD PAGING IN TEL M...

Page 12: ...ITY ATT OUTPUTS SPK ZONES AC IN 50 60Hz DO N P A REC LINE IN 5 4 0dB L R REMOTE 300W AM GND FM 75W POWER L R 4 SERIAL NO WARNING TO REDU OR ELECTRIC SHOCK D EQUIPMENT TO RAIN OR EACH ZONE 50W MAX MAX...

Page 13: ...ES DM 100 ON DM 100 OFF 7 DM 100 ON OFF RJ45 4 PAIRS LAN CABLE 100m 9 OUT LINK 10 AUX INPUT 11 AUDIO OUT GAIN RC 100 2 1 PRIORITY SLAVE SLAVE RC 100 PRIORITY RC 100 TALK S W SLAVE RC 100 PRIORITY RC 1...

Page 14: ...AL SIGNAL TO NOISE RATIO T H D POWER CONSUMPTION 1 8 POWER CURRENT DRAW 120V 230V 1 3 POWER CURRENT DRAW 120V 230V RATED POWER CURRENT DRAW 120V 230V GENERAL POWER SOURCE OPTION DIMENSIONS mm inches W...

Page 15: ...PHANTOM POWER GAIN 50 10dB CHIME R M 1 2 3 MIC PROT 24V MESSAGE FIRST PROT CHIME P T T REMOTE SLAVE REMOTE PRIORITY ATT ALL CALL M6 M5 M4 M3 M2 M1 REPEAT STOP START STOP COM G BUSY DRIVER SERIAL TO PA...

Page 16: ...ZA 1120A 1240A OPERATING INSTRUCTIONS ATT ZONE AMPLIFIER...

Reviews: