P/N 960-100175R_Rev. 6 {EDP #200824}
© 2016, JAPAN CASH MACHINE CO., LTD.
2 - 1
S e c t i o n 2
This section provides installation/operation
instructions for the Taiko
™
Series Banknote Accep-
tor (PUB-7/11). This section contains the
following information:
•
Installation and Removal
•
Power Harness Wiring Procedure
•
Clearing a Banknote Jam
•
DIP Switch Configurations
•
Error Codes and Conditions
•
Interface Connector Pin Assignments
•
Cleaning Procedures
•
Standard Interface Circuit Schematics
•
Operational Flowcharts
Installation and Removal
Installing the PUB-7/11 Taiko Bezel
To install or remove a Taiko
™
PUB-7/11 Unit
Bezel in a door or wall perform the following steps:
1. Create the correct sized opening required to
install the Taiko™ Bezel, using the Panel Cut-Out
Dimensions shown in Figure 2-1.
2. Open the Upper Guide in the arrow direction
shown in Figure 2-2 by pressing in on the Upper
Guide Open/Close Buttons.
3. Hold the Taiko™ Unit by placing your hand
under the Upper Guide (Figure 2-3 j).
4. Slightly press down on the Bezel and raise the
rear Taiko™ Unit body (Figure 2-3 k).
5. Slide the body up and back to detach it from the
Bezel section (Figure 2-3 l).
6. Remove the two (2) Bezel Brackets and the two
(2) Hexagonal Nuts from the Bezel.
7. Insert the Bezel into the previously cut-out
area in the Door Front Panel as shown in
8. Set the Bezel in the door hole and attach the two
(2) Bezel Brackets to the back side of the Bezel
using the two (2) Hexagonal Nuts previously
removed (Figure 2-5).
2 INSTALLATION
WARNING: Turn the equipment power OFF before removing or replacing any
Taiko™ components!
Figure 2-1
Taiko Bezel Cut-Out Dimensions
Figure 2-1
Taiko Bezel Cut-Out Dimensions
(4
3
mm)
Radius
Figure 2-2
Figure 2-2
Opening Taiko’s Upper Guide
Figure 2-3
Figure 2-3
Removing the Taiko Bezel
j
k
l
Figure 2-4
Figure 2-4
Installing the Taiko Bezel
WARNING: Tightening the Nuts with too
much force can damage the Bezel. The
necessary torque is 6.196 inch-lbs
(0.7Nm).