2
2.2 Emergency cash drawer release
In the unlikely event of a machine malfunction or a prolonged power failure, the model J3500E is
equipped with an emergency cash drawer release.
The release is located on the rear underside of the cash drawer. To manually release the drawer,
carefully lift one side of the ECR with your left hand and push the release tab with the other.
FIGURE 2-2 Emergency Drawer Release
2.3 Preparation for use
Dip switch setting
Dip switch is located on the front center of the main PCB.
It is used for initialization and hardware configuration purposes.
1: ON
initial reset
OFF
normal operation
Initial reset procedure
(a)
Initial reset
(1)
set DIP sw1 to ON.
(2)
Power ON.
Clears RAM work area only (current transaction)
Does not effect totals/counters or program memory.
Operation mode become “P” mode.
(b)
RAM clear(all clear)
(1)
Turn the mode lock key to the “P”mode.
(2)
Set DIP sw1 to ON
(3)
Power ON while depressing the tenkey ”1”.
(4)
All clear is displayed.
Clears all Totals/counters and user programmed memory. Loads default operation program
After all clear operation, you must preset the date and time in “X” mode.
The machine does not work without setting date and time.
Rear
BOTTOM VIEW
FRONT
release