Safety edge inhibition

The panel includes a function that automatically inhibits the safety edge for the last 4cm of the run.

Continuous floor and ceiling level correction

The panel includes a continuous floor and ceiling level detection and correction system that operates in operating mode

whenever the door has been fully opened or closed from its end positions.

Receiver operation

Upon receiving a code, the equipment checks whether it is in its memory, activating the corresponding relay.

Manual programming

Normal programming

Press the PANEL PROG button for 1 sec. The programming pilot light will come on and the equipment will emit an acoustic sig-

nal. The equipment will enter normal programming. Send the code and the channel to be programmed by pressing the trans-

mitter.

Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec. After 10 seconds without pro-

gramming or by pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic sig-

nals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5 sec. acoustic signals and exit

programming.

By pressing the transmitter channel, opening and closure is activated in automatic operating mode.

Open/close programming

In normal programming, press the PANEL PROG button again and keep it pressed down until the red pilot light flashes and the

equipment emits a short acoustic signal. The equipment will now have entered open/close programming. Press the required

channel of the transmitter to be programmed. The first channel opens and the second closes (3rd channel opens and 4th chan-

nel closes).

Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec. After 10 seconds without pro-

gramming or by pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic sig-

nals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5 sec. acoustic signals and exit

programming.

Each transmitter channel can be configured independently on the equipment, occupying only
one memory position.

Programming by radio

To enter programming, press the first two buttons on a transmitter that has already been registered on the equipment. The

equipment will issue a 1 sec. acoustic signal. On pressing any button on the new transmitter, the equipment will issue another

1 sec. acoustic signal to indicate that it has been memorised. The new transmitter will maintain the same channel con-

figuration as the transmitter registered.

After 10 seconds without programming or by quickly pressing the programming button or pressing the first two transmit ter but-

tons, the equipment will exit programming mode, issuing two 1 sec. acoustic signals.

jcm

technologies

7

Summary of Contents for EASY-ROLL

Page 1: ...User s Manual EASY ROLL...

Page 2: ...be handled when the appliance is disconnected from the mains The instructions for using this equipment must remain in the possession of the user European door normative EN 12453 and EN 12445 specify t...

Page 3: ...erature 20 C to 85 C Airtightness IP54 with IP65 packing seal Box dimensions 140 x 220 x 55 mm RadioBand characteristics Parameter Value Frequency 868 90MHz Memory 6 RADIOBAND T Range guaranteed 10 me...

Page 4: ...pen and close The first press opens the second press stops until the limit switch and the third closes Stop STOP Contact normally closed This detains the operation on standby for a new order Where not...

Page 5: ...hen pressed for the second time and it closes when pressed for the third time if the end of the opening time is complete If not it continues to open 3 Open close dead man operating Turn options 1 and...

Page 6: ...for the security open contact No auto test carried out 5 OPEN STOP OPEN The panel always opens until the end of the opening time Alternative operation open stop close stop 6 AUTO CLOSE Automatic clos...

Page 7: ...ming press the PANEL PROG button again and keep it pressed down until the red pilot light flashes and the equipment emits a short acoustic signal The equipment will now have entered open close program...

Page 8: ...the equipment will exit programming mode issuing two 1 sec acoustic signals RADIOBAND RC RCS OPERATIONS Use the PROG RB programming button to programme the safety edges Follow the RADIOBAND system ins...