CAPTIVE SYSTEM
jcm
technologies
23
In case of operating without ATEST signal, it is necessary to work in ATEST positive way. In order to comply with the EN
ISO 13849-1: 2008 safety standard, you must connect this signal to test the system.
ON/WORK mode
The operating mode is selected by the SW2 of the receiver. This selector is necessary when working with optical safety
edges. All transmitters in the receiver work in the same way. It will be necessary to reset the receiver when changing
the operating mode with transmitters already memorized.
With standard optical safety edges, WORK mode must be used due to high consumption of the optical elements.
With OSE-S7502 "always on" optical safety edges, both modes are allowed. In ON mode, the system becomes
universal for any control panel. In WORK mode the battery life is maximized thanks to the shutdown of the optical
elements.