Configuration 

 

OPERATION MODE CONFIGURATION 

The  equipment  can  operate with proximity  system or  Free system,  but not  both at  once. Select  the switch position for the  desired 
performance. 

 

SWITCH 

OFF 

ON 

Proximity mode BUS-L (EVOPROX) 

Hands free mode with FREE 15R 

Note: A wrong selection of the proximity device that is being used will cause an inoperation or a power consumption increase 
during the emergency mode. 

 

RECEIVER SETTINGS 

It can be operate with Soft-Assistant to manage code memory of the receiver. 

 

SETTING TIME RELAY ACTIVATION 

Press the programming button for 1s, the LED turns on and the equipment beeps. Hold down the programming button and the 
equipment enters in a cyclical sequence of four beeps. Each of these signals indicates a preset time relay activation. Stop 

pressing the button beeps when the desired time appears. 

Acoustic signal 

Time relay activation 

1            

 

3 seconds 

2            

 

5 seconds 

3            

 

7,5 seconds 

4            

 

9,5 seconds 

 

Operation 

 

NORMAL OPERATION 

The R1 light indicator is activated each 5 seconds showing the correct power supply of the equipment. 

 

When the equipment receives a code it checks automatically if it is in the memory, and it actives the corresponding relay. 
  
If the battery is not connected or it is not working properly, the receiver will make three acoustic signs each time it is activated by 

the transmitter. 
 

EMERGENCY MODE 

If the power supply falls down and the battery is connected, the system will switch to emergency mode. 

-

 

If it is working with the MOTION system, the EVOPROX will be activated every 8 seconds out of 22. During this period, the 
activation will be ready only one second 

-

 

If it is working with the FREE system, the FREE 15R will be available 1 second out of 10. 

 

Programmation 

 

MANUAL PROGRAMMING 

Press  the  receiver  programming  button  for  1  second,  the  light  indicator  will  turn  on  and    an  acoustic  signal  will  be  heard.  The 
receiver will enter standard programming. Send the code and the channel to be programmed by pressing the corresponding button of 
the transmitter. 

 
Every  time  a  transmitter  is  programmed,  the  receiver  will  issue  an  acoustic  signal  for  0.5  sec.    After  10  seconds  without 

programming, or pressing the programming button, or the first two buttons of the transmitter (depending on the programming mode) 
the  receiver  will  exit  programming  mode  issuing  two  acoustic  signals  of  1  sec.  If  upon  programming  a  transmitter  the  receiver 
memory is full, it will issue 7 acoustic signals of 0.5 sec. and exit programming. 

 

TOTAL RESET 

In programming mode, the programming button is held down and the “MR” reset jumper is bridged for 10 seconds. The receiver will 
issue 10 short acoustic warning signals followed by others at a faster pace to indicate that the operation has been successful. The 

receiver is now in programming mode. The programming light indicator will also follow the sound indications issuing intermittent 
lights. 
After 10 seconds without programming or pressing the programming button, the receiver will exit programming mode, issuing two 

acoustic signals of 1 sec. 

Summary of Contents for BASELEC500

Page 1: ...Hz Codificaci n C digo cambiante de alta seguridad Memoria 500 c digos N mero de rel s 1 Alimentaci n 230V ac 10 Consumo reposo funcionamiento 37mA 53mA Entrada Intercom 12 24V ac dc Salida electrocer...

Page 2: ...3200348_BASELEC500_2ID_Rev01 Page 2 8 Instalaci n y conexiones CONEXIONES INSTALACI N DESATORNILLAR SOPORTE BATERIA FIJAR CAJA EN PARED COLOCAR BATERIA Y ATORNILLAR SOPORTE CONECTAR BATER A BLANCO NEG...

Page 3: ...Si se desconecta la alimentaci n y el equipo tiene la bater a conectada el sistema pasar a modo de funcionamiento de emergencia Si est funcionando con sistema MOTION el Evoprox estar activado 8 segund...

Page 4: ...Desconectar la alimentaci n antes de efectuar cualquier manipulaci n en el equipo En cumplimiento de la directiva europea de baja tensi n se informa de los siguientes requisitos Para equipos conectad...

Page 5: ...Coding High security rolling code Memory 500 codes Relay contacts 1 Power supply range 230V ac 10 Standby Op Consumption 37mA 53mA Intercom input 12 24V ac dc Electrolock output 12Vdc Acess control o...

Page 6: ...0348_BASELEC500_2ID_Rev01 Page 6 8 Installation and connections CONNECTIONS INSTALLATION UNSCREW THE BATTERY SUPPORT FIX THE BOX TO THE WALL PLACE BATTERY AND SECREW SUPPORT CONNECT THE BATTERY WHITE...

Page 7: ...battery is connected the system will switch to emergency mode If it is working with the MOTION system the EVOPROX will be activated every 8 seconds out of 22 During this period the activation will be...

Page 8: ...he power supply before handing the unit In compliance with the European Directive low voltage electrical equipment we hereby inform users of the following requirements For units which are permanently...

Reviews: