F.3 Time configuration
Allows the unit’s date and time to be configured, enabling the correct management of events.
The event memory stores the date and time of the event, the type of event, the code, the number and the model of the device.
The events can be shown using the Assistant programming tool.
Display
Configuration
Values(xx)
d_xx
day
01 - 31
M_xx
month
01 - 12
A_xx
year
00 - 99
h_xx
time
00 - 23
m_xx
minutes
01 - 60
If no action is performed, the equipment exits the program automatically after a period of 60 seconds and emits two short
beeps.
F.4 Relay configuration
Allows configuration of the relay activation timing, and in relay 4, allows configuration of timing if it is to be used as an anti-
panic function.
Display
Bi-stable configuration
(biES)
Impulse configuration
(Im__)
Anti-panic configuration
(Al__)
r1
Yes
01 – 30 seconds
No
r2
Yes
01 – 30 seconds
No
r3
Yes
01 – 30 seconds
No
r4
Yes
01 – 30 seconds
01 – 15 minutes
To return to the previous menu, move to the ----- position and press the C key.
If no action is performed, the equipment exits the program automatically after a period of 60 seconds and emits two short
beeps.
Alarm function
This function is only configurable using the Assistant programming tool and is only available on proximity elements where the
alarm function is implemented.
Allows for the enabling of a different relay to that programmed by default, reading the device a certain number of consecutive
times in a maximum time of 5 seconds between each reading.
Example: the proximity element enables relay 1 by default and with the alarm function it will enable relay 3 on reading the
device 4 consecutive times.
Mensajes
Display
Type of message
OcuP
Displayed when attempting to register a code in a position which is already taken Skips to the first free
position emitting a beep.
rEP
Displayed when attempting to register a code which is already programmed in another position. Skips
to the position where the programmed code is located, emitting a beep, and allows the device to be
reprogrammed.
no
Displayed when pressing a device which is not programmed in the unit.
datE Displayed when a proximity element is used outside its period of validity.