Advanced Mode (Mod2)
Allows the complete management of the unit: programming (F.1), cancellations (F.2), time configuration (F.3) and relay con-
figuration (F.4).
Function is changed using
. To confirm each option, press the C key.
Events monitoring (only visible using the Assistant).
F.1 Programming
Standard programming (Mr_P) (default option, multi-channel mode)
The screen displays the first empty memory position in which we can program a code (M001). With the
keys we can
increase or decrease the memory position. If
are kept pressed down for more than 3 seconds, the positions increase
or decrease rapidly. If a memory position is taken, this will be indicated by a dot on the screen.
To return to the previous menu, move to the ----- position and press the C key.
If no action is performed, the equipment exits the program automatically after a period of 60 seconds and emits two short
beeps.
Special programming (Mr_1 … Mr34)
Allows selection of the relays that will be activated with the channel programmed from the transmitter. Example: If you wish to
program Channel 1 of the transmitter so that relays 1 and 3 activate, you need to select option Mr13.
The screen displays the first empty memory position in which we can program a code (M001).
Using
, we can increase or decrease the memory position. If
are kept pressed down for more than 3 seconds,
the positions increase or decrease rapidly. If a memory position is taken, this will be indicated by a dot on the screen.
To return to the previous menu, move to the ----- position and press the C key. If no action is performed, the equipment exits
the program automatically after a period of 60 seconds and emits two short beeps.
F.2 Cancellations
Individual cancellation
To delete a code, move to the position where the code is located and press the C key. The dot indicating a taken position will
disappear. The equipment will emit three short beeps.
To return to the previous menu, move to the ----- position and press the C key.
If no action is performed, the equipment exits the program automatically after a period of 60 seconds and emits two short
beeps.
Total reset
Move to any memory position and keep the C key pressed down for more than 5 seconds. The equipment will emit 10 warning
beeps followed by others at a more rapid frequency, indicating that the operation has been performed.