Operating

Start

Contact normally open to open and close. First time the button is pressed, it
opens; the second time (if it has not reached the end of the run), it stops and
the third time it closes. If it is pressed while the door is closing, it will stop and
invert the operation

Stop (STOP)

Contact normally closed. This detains the operation on standby for a new
order. Where not used, turn option 1 on the input switch to ON

Open (ABR.)

Contact normally open to open. If it is pressed while the door is closing, it will
stop and open

Close (CER.)

Contact normally open to close. If it is pressed while the door is closing, it will
stop and close

Security contact (SEC.CL)

Contact normally closed, photocell or magnetic detector type. This acts on
opening and closing, causing stoppage and inversion. Where not used, turn
option 2 on the input switch to ON

Security edges (S.EDGE)

Resistive contact for two parallel resistive security edges. This acts on clos-
ing, causing stoppage and inversion. Where not used, turn option 3 on the
input switch to ON. Where option 6 of the options switch is turned to ON, the
band is inhibited during the last 4 cm of door closure

Ends of run (FC.CL/FC.OP)

Contacts normally closed to mechanically indicate the open and closed end
of run. Where not used, turn option 4 or 5 on the input switch to ON

24 Vac output

To power any equipment at a voltage of 24 Vac with a maximum con-
sumption of 400 mA

Encoder input (+, S.H., -)

Allows for an NPN-type encoder (or sensor hall) to be connected at 5 Vdc,
necessary for the operation by pulses.necessary for the operation by pulses

Reference search function

If the panel loses power halfway through the operation, on receiving power it goes into reference search mode, in such a way

that the door will move until a mechanical stop or the end of the run is reached, with preference given to the opening reference,

if it exists. Reference search is indicated by the corresponding flashing of the SAFETY light (see table).

The Aut ref Search parameter (configurable by means of programmer) is selected if the user requires this automatic search or

wishes to wait for the START button to be pressed for the reference search.

The panel may lose the reference if the power is disconnected halfway

through the operation.

Door operation control function with external clock

By connecting an external clock or timer (normally open) between the common push button terminal (16) and the bridged Open

and Close terminals (17 and 18), it is possible to temporize the opening and closing of the door.

Back Jump Function

With this function, the panel causes a small delay in the door at the end of the operation to prevent voltage in the mechanism

or to avoid pressure on the safety edge, where applicable. The time of the delay can be defined using advanced programmer

parameters.

jcm

technologies

5

Summary of Contents for CONT-R15

Page 1: ...CONT R15 User Manual...

Page 2: ...witch jumpers 7 Buttons 7 Times 7 Programming 8 Self prgramming 8 Manual programming 8 Partial opening programming 8 Sensivity programming 8 Parameter configuration from programmer 9 Receiver operatio...

Page 3: ...ry 230V ac Transformer 230Vac power supply L 9 24V dc motor 17 Open OPEN NO 2 Primary 230V ac Transformer 230Vac power supply N 10 Encoder 18 Close CLOSE NO 3 Secondary 0V ac Transformer 11 Encoder S...

Page 4: ...ghtness IP54 Equipment category Class II Base plate size 160x83x27 mm Box size 225x195x85 mm Installation Disconnect the power supply whenever you proceed to the installation main tenance or repair of...

Page 5: ...ON 24 Vac output To power any equipment at a voltage of 24 Vac with a maximum con sumption of 400 mA Encoder input S H Allows for an NPN type encoder or sensor hall to be connected at 5 Vdc necessary...

Page 6: ...n Does not inhibit the security edge default option 7 DEAD MAN Dead man operations Semi automatic or automatic oper ations default option Input switch Option No Upper position ON default option Lower...

Page 7: ...amming is carried out by pulses or by time With the jumper at ON the panel will be programmed by pulses and with the jumper removed it will be programmed by time Current limit level switch jumpers JP4...

Page 8: ...chanical stops are not used on either of the two ends of the door the START button must be pressed to indicate the limit of the run at the end of the door without the limit switch or mechanical stop M...

Page 9: ...ogrammer instruction manual for further information Operation by Time Indicates if the panel is programmed to operate by time Operation by Pulses Indicates if the panel is programmed to operate by pul...

Page 10: ...ill now have entered programming for ped estrian function Press the required channel of the transmitter to be programmed The first channel opens and the second closes 3rd channel opens and 4th channel...

Page 11: ...Hz 868 MHz This acts on the panel with transmitters proximity keys or smart cards in the same way as the start button Traffic light card Flash card TL CARD Traffic light card This carries out two diff...

Page 12: ...ce not reached 4 4 flashes off No encoder pulses 5 5 flashes off Panel programmed without references 6 6 flashes off Internal error Use of the equipment This equipment is designed to automate garage d...

Reviews: