P/N 960-100189R_Rev. 4 {EDP #148850}
© 2016, JAPAN CASH MACHINE CO., LTD.
A - 5
Troubleshooting
VEGA™ Series Banknote Validator
Section A
Table A-3
Reject Codes
On-line Off-line
Error
Causes and Solutions
Color
Flashes
(Interval
[msec])
Color
Flashes
(Interval
[msec])
Yellow
1
(120)
Yellow
1
(120)
Transport Slips
Detect abnormal Banknotes transportation while the transport is
processing (Transport Slippage). Sensor does not detect a Banknote
even though the number of Banknotes transported is more than the
accepted value.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors.
[Relative Parts] Feed Motor, Escrow Sensor, Store Flap Sensor,
Validation Sensor
If the error is not resolved, change the above relative part or parts.
Yellow
3
(120)
Red
Transport Time Out
Detect an abnormal Banknotes transportation error when transporting or
rejecting Banknotes (e.g., Transportation Locks-up or its operation is too
slow). Sensors do not detect movement even though Banknote
transportation time is longer than the accepted value.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors.
[Relative Parts] Feed Motor, Escrow Sensor, Validation Sensor
If the error is not resolved, change the above related part or parts.
Yellow
Red
3
(120)
Yellow
3
(120)
Blue
Transport Motor
Lock-up
While operating the Feed Motor, no pulse inputs exist greater than the
rated value (when a Banknote is in transport position where it can be
returned, reject the Banknote).
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors.
[Relative Parts] Feed Motor
If the error is not resolved, change the above related part.
Yellow
Blue
3
(120)
Yellow
3
(120)
Green
Transport Speed
High
While performing a transportation process, the pulse interaction was
shorter than the accepted value.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors.
[Relative Parts] Feed Motor
If the error is not resolved, change the above related part.
Purple
Green
3
(120)
Yellow
3
(120)
Red
3
(120)
Abnormal Timing
Response
Sensor detected a Banknote remaining in path or none present during
an abnormal timing interval.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors.
[Relative Parts] Intake Sensor, Stack-in Sensor, Store Flap Sensor,
Escrow Sensor, RC Flap Sensor, Validation Sensor
If the error is not resolved, change the above related part or parts.
Yellow
3
(120)
Blue
Side Sensor
Problem
The Side Sensor detected a level in-between limits before it passed in
the Banknote through the Guide Sensor, and after it passed the
Banknote through the Side Sensor, and the value was greater than an
acceptable value.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors
[Relative Parts] Side Sensor
If the error is not resolved, change the above related part.
White
Yellow
3
(120)
Reject Code Table
Table A-3 lists the VEGA Unit’s Reject Codes.