6 - 2 3
Calibration and Testing
UBA Pro RT/RQ™ Series Banknote Recycler
Section 6
7. Remove the Recycler from the RT Transport.
8. Lift the Front Transport to block Note Position
Sensor 1 and 2.
9. Cover the Note Position Sensor 3 with a
Banknote.
10. The RT/RQ Unit Status LED will be lit at Cyan
when the Sensors function properly.
11. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
Note Position Sensor A - C Test
(RT Transport)
To run the Note Position Sensor A - C Test on the
RT Transport side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-114).
3. Set the DIP Switches of the RT/RQ Unit as below
(Figure 6-115).
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
6. To start the Test, set the UBA Pro DIP Switch #8
to
OFF
(Figure 6-117).
7. Remove the Recycler from the RT Transport to
block the Note Position Sensor A through C.
8. The RT/RQ’s Status LED will be lit at Magenta
when the Sensors function properly.
9. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
Figure 6-112
Note Position Sensor 1 - 3 Test 5
Figure 6-113
Note Position Sensor 1 - 3 Test 6
Figure 6-114
Note Position Sensor A - C
Test (RT Transport) 1
DIP Switches #1, #2, #6, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-115
Figure 6-115
Note Position Sensor A - C
Test (RT Transport) 2
DIP Switches #1, #4 ON
ON
1
2
3
4
5
6
7
8
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-116
Figure 6-116
Note Position Sensor A - C
Test (RT Transport) 3
Green
ON
OFF
Figure 6-117
Figure 6-117
Note Position Sensor A - C
Test (RT Transport) 4
DIP Switch #8 OFF
ON
1
2
3
4
5
6
7
8
Figure 6-118
Figure 6-118
Note Position Sensor A - C
Test (RT Transport) 5