Surface Replication Kit

with Microset® Compounds

USER MANUAL

Scan QR Code (with 

smartphone camera) 

to view a short training 

video on our website. 

JCC DOC#

 

B5 March-2020

Summary of Contents for 4400M

Page 1: ...oll Free 866 358 9955 Fax 626 358 1448 1005 S Mountain Ave Monrovia CA 91016 4400M Surface Replication Kit with Microset Compounds USER MANUAL Scan QR Code with smartphone camera to view a short training video on our website JCC DOC B5 March 2020 ...

Page 2: ...ds P N 4400 2RT RF 3 1 x Nozzle Pack 50 Pack P N 4400 31 4 1 x Pack of Backing Slides 50 Pack P N 4400 4 5 1 x Pack of Backing Paper 100 Pack P N 4400 5 6 1 x Tilting Stage Base P N 4400 7 7 1 x Tall Micrometer Base P N 8400 27 8 1 x Carrying Case P N 4400 6 4400M Surface Replication Kit ...

Page 3: ...Compounds and Curing Times ...

Page 4: ...e slide release lever on dispenser body and insert piston slide Keep slide release lever raised and push slide back as far as possible Lower slide release lever Cartridge Clip Piston Slide Slide Release Lever https www microset co uk ...

Page 5: ... amount of compound on to waste paper MICROSET is supplied in a two part cartridge which is dispensed through a static mixing nozzle using a hand held dispenser The two components of the cartridge are mixed together as they pass through the static mixing nozzle during the dispensing procedure This ensures air free mixing and minimum wastage of material during application The curing rate for MICROS...

Page 6: ...overlap the previous one similar to welding When replicating vertical surfaces work upwards 2 Do not apply excessive hand pressure to the dispenser as this may damage the operating mechanism 3 Do not stop flow of the material through the nozzle for longer than the working life of the MICROSET grade being used Once the working life has been exceeded a new nozzle will be needed 4 If desired apply ba...

Page 7: ...the ambient temperature Choose a grade appropriate for the conditions See compound chart Air bubble entrapment Poor application Keep the nozzle in contact with the surface For blind holes place the lip of the nozzle at the bottom of the hole Replica distorts and resolution is poor when examined under a microscope Replica too soft when removed due to incomplete curing Extend curing period Replica s...