background image

4

JCB-PL10, JCB-PL20, JCB-PLT20, JCB-PLT40

Instruction Manual

JCB-PL10

AVERAGE ILLUMINATION

PLANAR INTENSITY DISTRIBUTION CURVE

Bare Lamp Photometric Data

Page 1 Of 

Goniophotometer Test Report

Measured Para  U: 0.0V  I: 0.0mA  P: 0.00W  PF: 0.000  

Lamp Name: 

Shape Size: 

Sur(m^2): 

Lamp Type: 

Lamp Spec: 

Manufactory: 

Weight(kg): 

Lamp ID: 

Protect Angle(Deg): 

a

t

a

D

 

c

i

r

t

e

m

o

t

o

h

P

a

t

a

D

 

e

c

r

u

o

S

 

t

h

g

i

L

Model

Nominal P(w)

Rated Flux(lm)

Illuminant QTY

Peak Value(cd)

Dw Flux Rate(%)

Down(C180-C360)

Efficiency(lm/w)

UP(C0-C180)

UP(C180-C360)

0.0

0.0

Planar Intensity Distribution Curve

0

695.9

0

.

8

4

0

.

0

0

1

0.0

0.0

0.0

Position

180.0,1.0

Up Flux Rate(%)

0.0

C0 Plane beam angle(50%):55.0(DEG)  C90 Plane beam angle(50%):54.8(DEG)

C0 Plane beam angle(50%)

C90 Plane beam angle(50%)

30°

60°

90°

120°

150°

180°

210°

240°

270°

300°

330°

700

560

420

280

140

0

C Angle Range:0 - 180(Deg)

5

4

 

:

)

g

e

D

(

l

a

v

r

e

t

n

i

 

C

1

 

:

)

g

e

D

(

l

a

v

r

e

t

n

i

 

a

m

a

G

Temperature(Deg): 27

Tester: 

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 50

Date: 2019-7-15

Gama Angle Range:-90 - 90(Deg)

 

:

k

r

a

m

e

R

0

7

0

.

0

1

 

:

)

m

(

e

c

n

a

t

s

i

D

4

Summary of Contents for JCB-PL10

Page 1: ...EN JCB PL10 JCB PL20 JCB PLT20 JCB PLT40 LED RECHARGEABLE POWER LIGHTS LED WORKLIGHTS INSTRUCTION MANUAL...

Page 2: ...2V batteries or two 7 4V batteries delivering runtime of up to 14 hours from a 3 4 hour charge time per battery The range offers a discharging battery indicator with indicator lights that turn off on...

Page 3: ...COB Chip 2 x 1616 COB Chip 4 x 1616 COB Chip CRI 70Ra Power Factor 0 9 Colour Temp 6500K IK Rating IK09 Life Expectancy 20 000 Hours Working Temp 10 C 40 C Battery 2 x 7 4V 4 4Ah 2 x 7 4V 4 4Ah 2 x 2...

Page 4: ...0 C360 0 0 0 0 Planar Intensity Distribution Curve 0 695 9 0 8 4 0 0 0 1 0 0 0 0 0 0 Position 180 0 1 0 Up Flux Rate 0 0 C0 Plane beam angle 50 55 0 DEG C90 Plane beam angle 50 54 8 DEG C0 Plane beam...

Page 5: ...80 C360 0 0 0 0 0 1614 5 2 8 4 0 0 0 1 0 0 0 0 0 0 Position 180 0 1 0 Up Flux Rate 0 0 Planar Intensity Distribution Curve C Angle Range 0 180 Deg 5 4 g e D l a v r e t n i C 1 g e D l a v r e t n i a...

Page 6: ...C360 0 0 0 0 Planar Intensity Distribution Curve 0 1563 8 3 8 4 0 0 0 1 0 0 0 0 0 0 Position 0 0 0 0 Up Flux Rate 0 0 C0 Plane beam angle 50 56 5 DEG C90 Plane beam angle 50 56 5 DEG C0 Plane beam an...

Page 7: ...360 0 0 0 0 Planar Intensity Distribution Curve 0 3301 9 4 0 5 0 0 0 1 0 0 0 0 0 0 Position 0 0 0 0 Up Flux Rate 0 0 C0 Plane beam angle 50 55 9 DEG C90 Plane beam angle 50 55 2 DEG C0 Plane beam angl...

Page 8: ...sk of fire or burns DO NOT attempt to open disassemble modify or service the battery DO NOT expose to temperatures above 40 C DO NOT crush puncture short external contacts or dispose of in fire or wat...

Page 9: ...the mains power supply DO NOT use if worn or damaged Check cables are always protected against short circuit and overload IMPORTANT Check that the voltage marked on the charger plug is the same as th...

Page 10: ...ct the 230V charger or 12 24V DC charger to a power supply The LED battery indicator will flash whilst charging and remain constant when fully charged Disconnect the charger from the worklight when it...

Page 11: ...truction manual provided The product has not been subject to insufficient servicing and maintenance The product has not been subject to any abnormal environmental conditions or inappropriate operating...

Page 12: ...12 JCB PL10 JCB PL20 JCB PLT20 JCB PLT40 Instruction Manual NOTES...