Depress the switch trigger to start 
the tool. Move the drill bit into the 
workpiece, applying only enough 
pressure to keep the bit rotating. Do 
not force or apply side pressure to 
elongate a hole.

tungsten carbide drill bits 

should always be used for 

concrete and masonry. when 

drilling in metal, only use HSS drill 

bits in good condition. always use 

a magnetic bit holder (not 

included) when using short 

screwdriver bits. when screw-

driving, apply a small quantity of 

liquid soap or similar to the screw 

threads to ease insertion.

10. DISPOSaL Of an 

ExHauStED BattERy 

PaCK

 

To preserve natural 
resources, please recycle or 
dispose of the battery pack 

properly. This battery pack contains 
Lithium batteries. Consult your local 
waste authority for information 
regarding available recycling and/or 
disposal options. Discharge your 
battery pack by operating your drill, 
then remove the battery pack from 
the drill housing and cover the 
battery pack connections with 
heavy-duty adhesive tape to prevent 
short circuit and energy discharge. 
Do not attempt to open or remove 
any of the components.

11. OvERLOaD 

PROtECtIOn

When overloaded, the motor comes 
to a stop. Relieve the load on the 
machine immediately and allow 
cooling for approx. 30 seconds at 
the highest no-load speed.

12. tEMPERatuRE 

DEPEnDEnt OvERLOaD 

PROtECtIOn

When using as intended the power 
tool cannot be subject to overload. 
When the load is too high or the 
allowable battery temperature of 
75°C is exceeded, the electronic 
control switches off the power 
tool until the temperature is in the 
optimum temperature range again.

13. PROtECtIOn agaInSt 

DEEP DISCHaRgIng

The Li-ion battery is protected 
against deep discharging by the 
“Discharging Protection System”. 
When the battery is empty, the 
machine is switched off by means 
of a protective circuit: When this 
occurs your tool will not switch on. 
Remove and recharge the battery 
pack.

Summary of Contents for JCB-CD18Li

Page 1: ...SO53 3LE Customer Helpline 0845 600 5526 SAFETY AND OPERATING MANUAL CORDLESS COMBI DRILL JCB CD18Li Original Instructions...

Page 2: ......

Page 3: ...f electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounde...

Page 4: ...s ensure these are connected and properly used Use of dust collection can reduce dust related hazards 4 Power tool use and care a Do not force the power tool Use the correct power tool for your applic...

Page 5: ...er battery packs may create a risk of injury and fire c When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that...

Page 6: ...completed 14 Your drill and battery pack will be warm when working this is normal 15 Do not dispose of batteries in fire or with household waste Return exhausted batteries to your local collection or...

Page 7: ...r Helpline 0845 600 5526 3 Do not charge non rechargeable batteries 4 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to...

Page 8: ...ction manual Warning Wear ear protection Wear eye protection Wear dust mask Indoor use only Do not expose to rain or water Do not burn Do not dispose of batteries Return exhausted batteries to your lo...

Page 9: ...que adjustment ring 3 Two speed gear control 4 Forward Reverse rotation control 5 On off switch 6 Battery pack release button 7 Battery pack 8 Auxiliary handle 9 LED light COMPONENT LIST Not all acces...

Page 10: ...etermined according to EN 60745 Impact drilling into concrete Vibration emission value ah 13 8m s Uncertainty K 1 5m s Drilling into metal Vibration emission value ah 3 7m s Uncertainty K 1 5m s A wei...

Page 11: ...y significantly reduce the exposure level over the total working period Helping to minimize your vibration exposure risk ALWAYS use sharp chisels drills and blades Maintain this tool in accordance wit...

Page 12: ...r battery charger The Li ion battery is protected against deep discharging When the battery is empty the machine is switched off by means of a protective circuit The tool holder no longer rotates In a...

Page 13: ...Depress the On Off switch 5 to start and release it to stop your drill The on off switch is fitted with a brake function which stops your chuck immediately when you quickly release the switch It is a...

Page 14: ...topped 4 TWO SPEED GEAR CONTROL See 5 The drill has a two speed gear control designed for drilling or driving at LOW mark is 1 or HIGH mark is 2 speeds A slide switch is located on top of the drill to...

Page 15: ...direction Ensure the drill bit is in the center of the chuck jaws Finally firmly rotate the front chuck section in the opposite directions Your drill bit is now clamped in the chuck 6 TORQUE ADJUSTMEN...

Page 16: ...rgy has expired For manual screwdriver purposes the chuck is automatically locked when the tool is off 8 USING THE LED LIGHT See 9 The LED light allows you to keep a clear view under less illuminated...

Page 17: ...tions Discharge your battery pack by operating your drill then remove the battery pack from the drill housing and cover the battery pack connections with heavy duty adhesive tape to prevent short circ...

Page 18: ...st result 3 REASONS FOR DIFFERENT BATTERY PACK WORKING TIMES Charging time problems as above and having not used a battery pack for a prolonged time will reduce the battery pack working time This can...

Page 19: ...in your plug proceed as follows The wire which is colored blue must be connected to the terminal which is marked with N The wire which is colored brown must be connected to the terminal which is marke...

Page 20: ...in this warranty period we guarantee to Replace or repair all defective parts free of charge or Repair products free of charge or Replace the unit with a new or re conditioned unit free of charge Cond...

Page 21: ...Directive 2006 42 EC EC Low Voltage Directive 2006 95 EC EC Electromagnetic Compatibility Directive 2004 108 EC Standards conform to EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 EN 60745 1 EN 6074...

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: