C3
MAINTENANCE
9803/1250
C3
Issue 1
BREAKER DISMANTLING - STANDARD AND VIBRO-DAMPED (cont’d)
12 For vibro-damped handle breakers only
, remove
the four top cover retaining screws
P
and remove
the cover.
14 For vibro-damped handle breakers only
,
withdraw the remaining handle assembly
complete with handle pivot. Remove the springs.
!
!
WARNING
Accumulator
The breaker incorporates a pressure accumulator.
This accumulator is pressurised even when there is
no hydraulic pressure to the breaker. Attempting to
dismantle the accumulator without first releasing
the pressure can cause injury or death. Gas
pressure must be released before carrying out
further dismantling.
Note:
Once gas has been released, a special charging
tool (part no. 929/05800) is required to re-charge the
accumulator. Re-charging the accumulator must only
be undertaken by a suitably qualified person.
13 For vibro-damped handle breakers only
,
unscrew the handle pivot pin
Z
nearest the trigger
pin. Withdraw the handle assembly from the
control handles bracket.
15 For vibro-damped handle breakers only
, using
a press, remove roll pins
Q
from the nose. This
releases latch
R
, latch plunger
S
and the plunger
spring.
16
Remove the cover screw
T
to expose the
charging screw.