16
V
ER
T
EC
User’s Guide
AC POWER REQUIREMENTS
Standard JBL DrivePack systems are equipped with a DP multi-channel Crown Class-I power amplifier and
loudspeaker specific DSP electronics and require appropriate AC power.
CAUTION:
In compliance with safety agency criteria and proper system operation, it is critical
that the system installer observe all electrical safety practices at all times and provide proper earth
grounding for all AC Power connections.
AC POWER CORD KIT
Convenience 10VAC North America NEMA 5-15 Edison type AC plug to PowerCon® connector and
0V Europe CEE 7/7 Schuko type AC plug to PowerCon connector cord sets are provided with this JBL
DrivePack product for light-duty shop testing or system configuration type use.
One spare gray Neutrik (P/N NACFCB) PowerCon connector is included in the AC Power Cord Set for your
convenience to create a pass-through AC power cable. To create a pass-through cable the system installer
may choose to simply cut off the AC plug from one of the provided AC cord sets and replace it with the
provided Gray PowerCon AC Outlet connector. Follow the wiring convention indicated in Table 1.
NOTE: Tighten set screws to .5Nm (1.8lb-ft) torque to prevent opening by hand.
USER-FABRICATED AC POWER DISTRIBUTION
System owners may choose to fabricate or purchase a custom AC Power cable infrastructure optimized for
their specific JBL DrivePack system configuration. See Table 1 for custom application wiring and connector
information.
NOTE:
Parts not provided.
CAUTION:
Do not exceed 80% current rating of any AC connector at any time! See Table for
current draw information.
Table 1. User-Fabricated AC Cable and Connector Information
AC Inlet Cable Connector
Neutrik PowerCon® NACFCA quick lock -pole A-type
cable connector for power inlet. Rated current per contact:
0 A (rms), Rated Voltage: 50VAC.
AC Outlet Cable Connector
Neutrik PowerCon® NACFCB quick lock -pole B-type
cable connector for power outlet. Rated current per contact:
0 A (rms), Rated Voltage: 50VAC.
Wiring
Cable: screw-type terminals or soldering nom. wire size/
contact: .5 mm² / 1 AWG
Wiring convention
Ground – Ground, Neutral – Neutral, AC Hot – AC Hot
With the two non-interchangeable types of connectors (A-type, B-type) it is impossible to produce a short
circuit. Mating connectors (combination) are identified by mechanical keyways and by color.
Table 2. Power Connector Coding
A-type (POWER INLET);
Cable connector: Blue
B-type (POWER OUTLET)
Cable connector: Gray, with
Blue bushing
www.audiovias.com