Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
Power on Delay time
3
sec.
functional
AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
10
@ Speaker Outputs
Turn-on Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Stand-by Input Power
14
Watts
15
@ nom. line voltage
Maximum allowable input power under
nominal Input voltage and frequency,
HOT or COLD operation.
Power Cons.@rated power
250
Watts
260
@ nom. line voltage
150 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
--
functional
Direct short at output
Thermal Protection
65 deg. C
--
functional
@1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection
YES
--
functional
DC present at Speaker Out leads
Relay or crowbar (for driver/fire
protection)
Line Fuse Rating
US Version
2.5
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
EU Version
1.6
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
SUB500
(SCS500.5
Subwoofer)
3
Summary of Contents for SUB500
Page 5: ...SUB500 SCS500 5 Subwoofer 4 ...
Page 10: ...SUB500 SCS500 5 Subwoofer 9 ...
Page 11: ...SUB500 SCS500 5 Subwoofer 10 ...
Page 12: ...SUB500 SCS500 5 Subwoofer 11 ...
Page 19: ...SUB500 SCS500 5 Subwoofer 18 ...
Page 20: ...SUB500 SCS500 5 Subwoofer 120v SCHEMATIC PAGE 1 19 ...
Page 21: ...SUB500 SCS500 5 Subwoofer 120v SCHEMATIC PAGE 2 20 ...
Page 22: ...SUB500 SCS500 5 Subwoofer 21 ...
Page 23: ...SUB500 SCS500 5 Subwoofer 230v SCHEMATIC PAGE 1 22 ...
Page 24: ...230v SCHEMATIC PAGE 2 SUB500 SCS500 5 Subwoofer 23 ...