OPTIONAL ACCESSORIES 

Listed below are some optional accessories which may be 
required for a particular installation. 

4. APPENDICES

DESCRIPTION

ORDER CODE

Intellivox wall bracket set (2 pcs), 25 mm, RAL 9007

802227

Intellivox hinge bracket 90°, RAL 9007

802005

Intellivox swivel bracket 90°, RAL 9007

806668

Intellivox swivel bracket 45°, RAL 9007

806678

Intellivox wall bracket set (2 pcs), 25 mm, RAL 9010

802225

Intellivox wall bracket set (2 pcs), 35 mm, RAL 9010

802235

Intellivox wall bracket set (2 pcs), 60 mm, RAL 9010

802260

Intellivox hinge bracket 90°, RAL 9010

802000

Intellivox swivel bracket 90°, RAL 9010

806608

Intellivox swivel bracket 45°, RAL 9010

806618

Small hinge set (2 pcs)

806602

Summary of Contents for Intellivox ADC H90 Mark II

Page 1: ...Installation Manual Intellivox ADC V90 H90 Mark II models Part Nos 576125 577125 577135 576126 577126 and 577136 EN54 24 ...

Page 2: ... models Document references Datasheet s 201104 V90MKII_2 x V90 datasheet 201104 H90MKII_2 x H90 datasheet Other references ITT report No 5136 BA 11 Notified product certification body Name Scientific and Research Centre for Fire Protection named after Józef Tuliszkowski National Research Institute Identification CNBOP PIB 1438 Address Nadwiślańska 213 Street 05 420 Józefów Poland Web www cnbop pl ...

Page 3: ...ate names mentioned in this manual may be registered trademarks or copyrights of their respective companies They are used here for indicative purposes only The information contained in this manual has been carefully checked for accuracy however no guarantee is given with respect to its correctness JBL Professional accepts no responsibility or liability for any errors or inaccuracies that may appea...

Page 4: ...JBL Professional Intellivox ADC Installation Manual 4 201402 ADCIM This page has been left blank intentionally ...

Page 5: ... 7 What s in the packaging 8 3 Installation Guide 9 Preparing For Installation 9 Intellivox ADC Connections 9 Mechanical Installation 10 Acoustic Centre 10 Mounting Options 11 Mounting Procedure 13 Wiring Details 14 Tap Setting 14 Correction EQ and High Pass Filter 15 Securing The Front Grill 15 Pilot Tone Indicator 16 Speaker Protection 16 4 Appendices 17 Appendix 1 Optional Accessories 17 TABLE ...

Page 6: ...as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 11 Refer servicing to qu...

Page 7: ... glass thermal fuse and ceramic terminal block EQ correction and high pass filter This manual covers Wiring and connection details Mechanical installation of the loudspeaker Please note that a full range of optional mounting brackets and connection coverboxes are available Please refer to our website for further details APPLICABLE MODELS AND VARIANTS The Intellivox ADC range is available in two ve...

Page 8: ...his document ADC Datasheet Box containing REF ITEM QTY USE A Mounting brackets 2 Speaker mounting B 30 mm hex headed screws with washers and wall plugs 4 Mounting bracket fixings wall C M5 x 12 mm pan head screws with shakeproof washers 8 Mounting bracket fixings loudspeaker D M4 x 10 mm round head screws with star retaining washers inc hex key 4 Grill security screws fig 2 Box contents A B C D ...

Page 9: ... plane This restriction does not apply to the Model H90 which is intended to be tilted downwards INTELLIVOX ADC CONNECTIONS The Intellivox ADC range loudspeakers are designed to be connected to 100 V or 70 V line speaker distribution systems They are not intended to be used with amplifiers which are designed to drive only low impedance i e 4 8 ohms loudspeakers However such amplifiers may be used ...

Page 10: ...icker see fig 3 The horizontal position is on the vertical centre line When calculating the positions for the mountings see below the distance from the acoustic centre to the top or bottom of the loudspeaker whichever is being used as the reference datum should be measured and then allowed for when marking the mounting positions The specification sheet supplied with each loudspeaker includes a mec...

Page 11: ...s radiating angle of the unit is correct fig 4 2 Acoustic centre reference point for H90 Reference point for acoustical mounting position H90 fig 4 3 H90 further mounting information A C H90 B MOUNTING OPTIONS Intellivox ADC models have two attachment points at the rear of the enclosure the loudspeaker should be mounted using these points Each point consists of four M5 threaded inserts and only th...

Page 12: ...rmation 3 The third method is to mount the column within a recess in the wall or dedicated mounting panel so that the front of the unit is flush This is a specialised mounting situation which will be encountered only rarely Access to the rear of the unit will still be required for the cables Because of the proximity of the unit to the walls particular attention should be paid to the avoidance of a...

Page 13: ...rs on one or both brackets if necessary 6 Attach the brackets to the rear of the loudspeaker using the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm diameter holes allow screwdriver access to the screw heads 7 Remove the front grill from the loudspeaker by gently lifting it at the locations of the snap on fittings which hold it in place Remove the protective foam Unscrew the fo...

Page 14: ...ng location the wiring scheme as indicated in fig 8 2 can be used Note that the application dependent safety regulations should be consulted in order to determine the proper grounding scheme TAP SETTING The internal 100 V 70 V transformer s primary tapping should be set according to the power requirements of the installation This figure will have been determined at the time of site analysis see al...

Page 15: ...ion The frequency response of the high pass filter is indicated in fig 10 2 Model V90 respectively fig 10 4 Model H90 The filter response is slightly dependent on the tap setting the curves are valid for the 100 W tap The factory default setting is with the high pass filter enabled this setting is most suitable for voice applications Note that the high pass filter might have to be disabled in case...

Page 16: ... Pilot tones of other frequencies and or levels may be used if the fault monitoring system demands them the illumination of the LED is not essential for such a system to operate correctly SPEAKER PROTECTION In a PA VA system it is important that the failure of a single loudspeaker does not incapacitate the rest of the system The ADC range of speakers incorporate three protection systems to prevent...

Page 17: ...802227 Intellivox hinge bracket 90 RAL 9007 802005 Intellivox swivel bracket 90 RAL 9007 806668 Intellivox swivel bracket 45 RAL 9007 806678 Intellivox wall bracket set 2 pcs 25 mm RAL 9010 802225 Intellivox wall bracket set 2 pcs 35 mm RAL 9010 802235 Intellivox wall bracket set 2 pcs 60 mm RAL 9010 802260 Intellivox hinge bracket 90 RAL 9010 802000 Intellivox swivel bracket 90 RAL 9010 806608 In...

Page 18: ...JBL Professional Intellivox ADC Installation Manual 18 201402 ADCIM This page has been left blank intentionally ...

Page 19: ...JBL Professional Intellivox ADC Installation Manual 19 201402 ADCIM This page has been left blank intentionally ...

Page 20: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2014 JBL Professional www jblpro com ...

Reviews: