IMPORTANT SAFETY INFORMATION

WARNING FOR YOUR PROTECTION

READ THE FOLLOWING:

KEEP THESE INSTRUCTIONS

HEED ALL WARNINGS

FOLLOW ALL INSTRUCTIONS

THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR 

SPLASHING LIQUID AND NO OBJECT FILLED WITH LIQUID, SUCH 

AS VASES, SHALL BE PLACED ON THE APPARATUS

CLEAN ONLY WITH A DRY CLOTH.

DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN 

ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.

DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS 

RADIATORS, HEAT REGISTERS, STOVES, OR OTHER APPARATUS 

(INCLUDING AMPLIFIERS) THAT PRODUCE HEAT.

ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE 

MANUFACTURER.

UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR 

WHEN UNUSED FOR LONG PERIODS OF TIME.

Do not defeat the safety purpose of the polarized or grounding-type 

plug.  A polarized plug has two blades with one wider than the 

other. A grounding type plug has two blades and a third grounding 

prong. The wide blade or third prong are provided for your safety. If 

the provided plug does not fit your outlet, consult an electrician for 

replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit from 

the apparatus.

Use only with the cart stand, tripod bracket, or table specified by the 

manufacture, or sold with the apparatus. When a cart is used, use 

caution when moving the cart/apparatus combination to avoid injury 

from tip-over.  Refer all servicing to to qualified service personnel. 

Servicing is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid has been 

spilled or objects have fallen into the apparatus, the apparatus has 

been exposed to rain or moisture, does not operate normally, or has 

been dropped.

POWER ON/OFF SWITCH: For products provided with a power 

switch, the power switch DOES NOT break the connection from the 

mains.

MAINS DISCONNECT: The plug shall remain readily operable. For 

rack-mount or installation where plug is not accessible, an all-pole 

mains switch with a contact separation of at least 3 mm in each pole 

shall be incorporated into the electrical installation of the rack or 

building.

FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE 

RECEPTACLE: Replace fuse with same type and rating only.

MULTIPLE-INPUT VOLTAGE: This equipment may require the use 

of a different line cord, attachment plug, or both, depending on the 

available power source at installation. Connect this equipment only 

to the power source indicated on the equipment rear panel. To reduce 

the risk of fire or electric shock, refer servicing to qualified service 

personnel or equivalent.

If connected to 240V supply, a suitable CSA/UL certified power cord shall 

be used for this supply.

SAFETY INSTRUCTIONS 

NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A 

POWER CORD.

WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS 

SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION.

The cores in the mains lead are coloured in accordance with the following code:

GREEN and YELLOW - Earth        BLUE - Neutral        BROWN - Live

As colours of the cores in the mains lead of this appliance may not cor-

respond with the coloured markings identifying the terminals in your plug, 

proceed as follows:
•  The core which is coloured green and yellow must be connected to the 

terminal in the plug marked with the letter E, or with the earth symbol, or 

coloured green, or green and yellow.

•  The core which is coloured blue must be connected to the terminal 

marked N or coloured black.

•  The core which is coloured brown must be connected to the terminal 

marked L or coloured red.

 

This equipment may require the use of a different line cord, attachment 

plug, or both, depending on the available power source at installation.  If 

the attachment plug needs to be changed, refer servicing to qualified ser-

vice personnel who should refer to the table below. The green/yellow wire 

shall be connected directly to the units chassis.

CONDUCTOR

WIRE COLOUR

Normal

Alt

L

LIVE

BROWN

BLACK

N

NEUTRAL

BLUE

WHITE

E

EARTH GND

GREEN/YEL

GREEN

WARNING: If the ground is defeated, certain fault conditions in the unit or 

in the system to which it is connected can result in full line voltage between 

chassis and earth ground. Severe injury or death can then result if the chassis 

and earth ground are touched simultaneously.

The symbols shown above are internationally accepted symbols 
that warn of potential hazards with electrical products. The light-
ning flash with arrowpoint in an equilateral triangle means that 
there are dangerous voltages present within the unit. The exclama-
tion point in an equilateral triangle indicates that it is necessary for 
the user to refer to the owner’s manual.

These symbols warn that there are no user serviceable parts inside 
the unit. Do not open the unit. Do not attempt to service the unit 
yourself. Refer all servicing to qualified personnel. Opening the 
chassis for any reason will void the manufacturer’s warranty. 
Do not get the unit wet. If liquid is spilled on the unit, shut it off 
immediately and take it to a dealer for service.  Disconnect the unit 
during storms to prevent damage.

Summary of Contents for CSM 28

Page 1: ...CSM 14 CSM 28 Commercial Series Mixer Operation Manual JBL Commercial Series...

Page 2: ...dy Parkway Sandy UT All Rights Reserved Contents Important Safety Instructions 3 JBL DECLARATION OF CONFORMITY 5 1 0 Welcome 7 1 1 Features 7 1 2 Front Control Panels and Indicators 8 1 3 Rear Panel C...

Page 3: ...nnect this equipment only to the power source indicated on the equipment rear panel To reduce the risk of fire or electric shock refer servicing to qualified service personnel or equivalent If connect...

Page 4: ...ix it with gen eral household waste There is a separate collection system for used electronic products in accordance with legislation that requires proper treatment recovery and recycling Private hous...

Page 5: ...Fluctuations and Flicker in Low Voltage Supply systems Rated Current less than or equal to 16A EN 55022 2010 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE Radiated Con...

Page 6: ...6...

Page 7: ...rol using the JBL CSR V control module 1 1 Features 4 or 8 inputs with 1 or 2 outputs respectively Ideal for commercial and industrial use System may be expanded by adding JBL Commercial Series Mixer...

Page 8: ...lume control will light green with signal presence while red indicates clipping i e the signal has reached the threshold of audible distortion F Tone Controls Bass and Treble potentiometers on each ou...

Page 9: ...ed input as well as two pins that when shortened together activates the priority function Ch1 G VOX Adjustment allows the input level to be set that will invoke priority override Ch1 H Line Level Outp...

Page 10: ...ced input as well as two pins that when shorted together activates the priority function Ch 1 5 F Remote Volume Control RJ45 style connector to connect to a JBL CSR V control module 100 240 V 50 60Hz...

Page 11: ...NE MIC LINE MIC LINE MIC LINE CH 1 VOX CH 5 VOX MONO SUM MONO SUM MONO SUM C E D H I G Line Out Line level output connector for each output channel H Mic Line Input Connector 3 pin Euro block connecto...

Page 12: ...thout the factory pack WARNING Before you start to set up your unit make sure you read and observe the Important Safety Instructions found at the beginning of this manual 2 2 Installing Your Unit CAUT...

Page 13: ...sions CSM 14 CSM 28 Figure 2 2 2 Mounting Kit long angle bracket CSM 14 only flat bracket CSM 14 only front angle bracket 218 44 mm 8 6 in 303 4 mm 11 9 in 43 3 mm 1 7 in 436 88 mm 17 2 in 303 4 mm 11...

Page 14: ...ds the same direction 2 Connect them with the flat bracket using the screws provided 3 Attach the front angle brackets to each side of the front of the assembly using the screws provided 4 Install the...

Page 15: ...ill be used for the mixer and attach the long angle bracket to the other side at the front using the screws provided 2 Attach the front angle brackets to the other side of the assembly as shown in the...

Page 16: ...ach the front angle brackets to each side of the front of the unit using the screws provided 2 Install the unit into the cabinet using the rack mount screws through the front angle brackets For detail...

Page 17: ...tors to connect audio devices for example CD DVD player However do not use both Euroblock and RCA audio input connectors on a single channel at the same time NOTE Custom wiring should only be performe...

Page 18: ...of a power amplifer such as a JBL Commercial Series Amplifer Figure 2 4 Wiring Audio System Professional audio system 100 240 V 50 60Hz 6W MADE IN MALAYSIA CAUTION TO REDUCE THE RISK OF ELECTRIC SHOC...

Page 19: ...g procedure when first turning on your system 1 Turn down the level of your audio source 2 Turn down the level controls of the amplifier 3 Power up the mixer The Power ring should change from green to...

Page 20: ...puts especially when MIC is selected from the MIC LINE switch Failure to do so may cause the amplifier or speaker to go into a protection mode or even cause damage 4 WARNING Never connect the output t...

Page 21: ...ockwise direction will reduce that level while the full clockwise setting will disable the VOX function 3 5 Priority Muting With CSM 14 Input Channel 1 may be used as a priority channel muting all oth...

Page 22: ...The Ch 1 Priority switch is closed muting all except Ch 1 input POSSIBLE REASON The power switch is OFF Note that while plugged in the unit will be in standby mode and the power ring will be green un...

Page 23: ...50K Phantom Power 27VDC Crosstalk Ref 5Vrms from Output Volume at mid position A weighted 1kHz 70 dB Tone Controls Bass and Treble non detented potentiometers on each channel Bass 10dB 100Hz Treble 1...

Page 24: ...Line Mic Input Gain Line Mic Input Gain Line Mic CH1 CH2 CH5 CH6 Phantom Power Mic Line Bal Mic Line Bal Mic Line Bal Mic Line Bal CH1 PTT CH5 PTT RCA MONO SUM RCA MONO SUM Gain 1 Gain 2 SPI SPI CH1...

Page 25: ...25 Tone Control Scaling Tone Control Scaling VCA 1 VCA 2 SW5 SW11 Master 1 Master 2 SPI 1 Clip 1 SPI 2 Clip 2 Bass Treble Bass Treble VCA VCA HPF HPF Line Out 1 Line Out 2...

Page 26: ...er Service your system installer or retailer On The World Wide Web www jblcommercialproducts com Professional Contacts Outside the USA Contact the JBL Professional Distributor in your area A complete...

Page 27: ...27...

Page 28: ...Part Number 5040964 Issue 01 14 JBL Commercial 8760 South Sandy Pkwy Sandy UT 84070 USA 801 566 8800...

Reviews: