![JBL 7130 Installation And Service Manual Download Page 10](http://html1.mh-extra.com/html/jbl/7130/7130_installation-and-service-manual_3567522010.webp)
5. Insert the frosted spacers into spaces 6 and 9.
6. Change the line cord and/or attachment plug to match
the supply source receptacle, or use a 120 V to 240 V A C
adapter (not provided). The adapter as well as the power
supply cord/or attachment plug used for 240 V A C mode
in the U.S., Canada and Japan shall be both U L listed and
C S A certified for use with said power source receptacle
and wired per Table 3. For use in other countries, adapter,
line cord and/or attachment plug selection shall be based
on local regulations.
7. In countries requiring line cords having wire codes different
from those noted in Step #6, the following suggestions
apply.
A. Remove the existing power cord from the chassis, and be
careful not to damage the Molex crimp terminal. If a
new Molex crimp terminal is not available, follow
steps B through H. If a Molex 1457-1 is available,
follow steps I through M.
B. Cut the existing single wire of the power cord having the
Molex crimp terminal 38 mm (1.5 in). Strip the cut end
of the wire 5 mm (3/16 in) and tin.
C. Obtain an Electrovert single strip, 6 E / 1 DS or equivalent.
D. Using the original power cord as a wire guide, strip the
outer covering from the new power cord and cut each
wire to the appropriate length, per the local wiring code.
E. Strip 5 mm (3/16 in) from the longest wire and tin.
F. Insert the wires from steps B and E into the Electrovert
terminal strip and tighten as required.
G. Solder the appropriate colored ground wire to solder
lug E l .
H. Insert the crimped Molex terminals into the Molex
commoning connector, spaces #1 and #16. Verify that
the remaining transformer crimp terminals and spacers
have been changed for 240 V A C use, per Table 3.
I. Using the existing power cable as a wire length guide,
strip the outer covering of the new power cord and cut
each wire to length per the local wiring code.
J . Strip 3 mm (1/8 in) from the longest wire.
K. Insert the wire into the Molex terminal per Figure 7,
and crimp, using a Molex tool model HTR 1031C or
equivalent.
L Solder the appropriate colored ground wire to solder
lug E l .
M. Insert the crimped Molex terminals into the Molex
commoning connector, spaces #1 and #16. Verify that
the remaining transformer crimp terminals and spacers
have been changed for 240 V A C use, per Table 3.
F I G U R E 10
9
W A R N I N G
T H I S S E C T I O N O F T H E M A N U A L
C O N T A I N S S E R V I C E I N S T R U C T I O N S
F O R U S E B Y Q U A L I F I E D S E R V I C E
P E R S O N N E L O N L Y .
V U M E T E R
C A L I B R A T I O N
C O N T R O L
GAIN R E D U C T I O N
C A L I B R A T I O N
C O N T R O L