![JBL 705P Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/jbl/705p/705p_owners-manual_3680440012.webp)
12
SOFTWARE-ENABLED FEATURES:
8
8
INPUT TRIM – Adjusts the level of the signal sent to the amplifier. Counter clockwise adjustment of the
ROTARY CONTROL reduces the speaker volume. Clockwise rotation increases speaker volume.
u
[0dB]
; -24dB – 0dB; 0.1dB adjustment resolution
8
8
INPUT SELECT - Allows monitoring of the following input sources:
u
{
[Analog]
; AES Ch1; AES Ch2; AES Ch1+Ch2}
8
8
AES LEVEL TRIM – Allows increase in gain or attenuation of digital signals.
u
[0dB]
; -24dB – +24dB; 0.1dB adjustment resolution
8
8
INPUT SENSITIVITY – 4 dBu when connecting high-output professional equipment or =10dBV
when connecting consumer level equipment.
u
{
[+4dBu]
, -10dBV}
8
8
USER EQ – USER EQ allows application of customized equalization based on preference, program material,
the requirement to monitor using an industry standard curve such as the X Curve, or to compensate for
transmission loss when the speaker is positioned behind a perforated cinema screen. The following controls
Enable/Disable the six bands of user EQ and provide access to the frequency, gain, and Q parameters of
each band.
u
Enable
{Engaged,
[Disengaged]
}
u
High Shelf
Frequency
8
[2kHz]
; 1/24th octave adjustment resolution
Gain
8
[0dB]
; -12dB – +12dB; 0.1dB adjustment resolution
u
Low Shelf
Frequency
8
[90 Hz]
; 1/24th octave adjustment resolution
Gain
8
[0dB]
; -12dB – +12dB; 0.1dB adjustment resolution
u
Parametric EQ Filter 1
Frequency
8
[1kHz]
; 20Hz - 20kHz; 1/24th octave adjustment resolution
Q
8
[1.0]
; 0.1 - 12; 0.1 adjustment resolution
Gain
8
[0dB]
; -12dB – +12dB; 0.1dB adjustment resolution
u
Parametric EQ Filters 2 - 4
8
Settings and default values same as PEQ Filter 1
Summary of Contents for 705P
Page 9: ...9 REAR VIEW 11 16 17 12 13 14 15 18 19 20 21 23 22...