Installation 

The 6007/6008 is suitable either for rack mounting in 
three EIA rack spaces without additional bracing or 
ventilation, or for counter-top placement. A full set of 

mounting hardware is packed with each unit. All exter-
nal connections and matching/bridging transformer 

option are made on the rear panel, Figure 1. 

Operating Temperature 

Because the 6007/6008 is cooled by convection, 

adequate clearance on the top of the unit must be 

provided to allow heat dissipation. The minimum 
recommended clearance when stacking the unit is 

one EIA standard panel space. 

A thermal switch in these units provides thermal 

protection by shutting down the amplifier if the internal 

temperature exceeds a safe operating level. The max-

imum allowable ambient temperature for the amplifier 

is  6 0 ° C (140°F). 

Operating Controls 

All operating switches, meter and level control are 
located on either the front panel or the rear panel, 

Figure 1. Control, meter and switch functions are given 

in Table 1. 

Input Connections 

Input connections to the amplifier may be either direct-

coupled or transformer-isolated at the LINE terminal 
strip, TB301, or the RCA-type phono jacks, J301, 

Figure 1. Direct-coupling is accomplished by con-

necting the center conductor of a shielded cable to 
LO and the shield lead to GND, or to either RCA-type 

phono jack. Table 2 lists the terminals and the RCA-

type phono jacks and applications of the LINE terminal 
strip. For transformer-isolated input, a 5195 matching/ 

bridging transformer [Figure 2} must be plugged into 

the 9-pin receptacle, XK301, Figure I.The input leads 

are connected to terminals HI, LO and GND of the 

LINE terminal strip. 

Output Connections 

Table 3 shows the output configurations available. 

TABLE 1 

Gain

 Controls input of amplifier. Control is wired 

ahead of the active circuitry and can be used as 
an input pad to prevent overloading and clipping 
of the non-inverting operational amplifier stage. 

NOTE: When the JBL 5195 matching/bridging 

transformer is used, the gain control is across 
the output of the transformer and therefore can-

not be used to prevent input transformer satur-

ation if excess input levels occur. 

Power Switch

 Applies primary power to amplifier. 

Meter

 Provides approximation of the output level, 

with  + 3 indicating that the amplifier is deliver-

ing its rated continuous sine wave power into 

4

 o. 

Low cut/out

 Offers the user a response roll-off of 6 dB per 

octave below 250 Hz. 

FIGURE 2 

Terminals 

RCA-Type 

Phono Jacks  Function 

Application 

Terminating Resistor  Special Instructions 

50

 kO 

G N D 

Direct Coupled 

For unbalanced high impedance 
(50 kO) sources 

— none— 

" A " o r " B " 

- n o n e — 

HI 
LO 
G N D 

Transformer isolated  Balanced high impedance 

(15 kO) source up to level of 

+ 15 dBm (with 5195 matching/ 
bridging transformer) 

— none— 

Balanced 600 O source up to 
level of +15  d B m (with 5195 

transformer) 

620 O,

 V

2

 W, connected 

to terminals  " H I " and "LO' 

Balanced 600 O source with 

up to level of 4  d B m with 
14 dB additional gain. 

—  n o n e -

Internal modification 
requiring service 

technician. 

Terminals 

(TB301) 

Terminals 

(TB302) 

Impedance 

Direct Out 

Transformer Out 

Link 

LO, Chassis  G N D 

4  0 ( 2 0 V) 

Yes 

None 

8 O . C 0 M 

8  0 ( 2 8 . 2 8 V) 

Yes 

" H I " t o " X F M R Primary" 

16

 a,

  C O M 

16  0 ( 4 0 V) 

Yes 

" H I " t o " X F M R Primary" 

70.7 V  C O M 

50 O 

Yes 

" H I " t o " X F M R Primary"' 

TABLE  2 / T A B L E 3 

Summary of Contents for 6007

Page 1: ...JBL 6007 6008 INSTALLATION AND SERVICE MANUAL...

Page 2: ...and shall disconnect easily at two plugs The amplifier shall occupy three standard EIA rack spaces and shall operate on 120 240 VAC 50 60 Hz LO CUT OUT SWITCH S301 TRANSFORMER OUTPUT TERMINAL STRIP T...

Page 3: ...9 pin receptacle XK301 Figure I The input leads are connected to terminals HI LO and GND of the LINE terminal strip Output Connections Table 3 shows the output configurations available TABLE 1 Gain Co...

Page 4: ...Figure 4a Install one jumper only per Figure 4b 3 Change the line cord and or attachment plug to match the supply source receptacle or use a 120 V to 240 V AC adapter not provided The adapter as well...

Page 5: ...ne screw 6 54959 1 lamp 7 54969 1 knob 8 4 3 m m 1 9 4 3 m m 1 10 4 3 m m 1 11 1 2 12 89508 1 10 32 Keps2 13 11908 1 No 6 inter tooth washer 14 54968 1 6 32 hex spacer 15 55523 1 switch 16 55039 1 pow...

Page 6: ...the decade for minimum distortion and sub stitute R37 with the closest EIA standard resistor 4 Verify distortion at 60 W and 1 W NOTE Amplifier must be warm before performing distortion measurements...

Page 7: ...THE MANUAL CONTAINS SERVICE INSTRUCTIONS FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY NOTES Graphs recorded using Radiometers BKF10 REC61S2and SMU401 Frequency response and distortion measurements mad...

Page 8: ...JBL Professional Division James B Lansing Sound Inc 8500 Balboa Boulevard Northridge California 91329 U S A 58028 PTM6007 8 10 78 Printed in U S A...

Reviews: