background image

O u t p u t

  C o n v e r s i o n 

For 150 O output, the following procedure should be 

used to parallel the windings of the output transformer, 

T 4 0 2 , Figure 8. 

1. Disconnect the unit from the power  s o u r c e . 

2. Clip the  B L U E and  V I O L E T output transformer leads 

from the printed circuit board at points #27 and #28. 

3. Solder the  B L U E transformer wire to the  G R E E N 

w i r e a t t h e O U T P U T t e r m i n a l s t r i p , T B 3 0 2 , marked HI. 

4. Solderthe  V I O L E T transformer wire to the G  R A Y wire 

at the  O U T P U T terminal strip,  T B 3 0 2 , marked  L O . 

The 5152 has been designed so that both the direct 

and transformer outputs may be used simultaneously. 

P r o o f of  P e r f o r m a n c e 

All performance  c h e c k s are in-cabinet procedures to 

be used for  c h e c k i n g specifications after repair or for 

incoming quality control inspection. 

N O T E : All  m e a s u r e m e n t s should be  m a d e with the 

unit and test equipment power  c o r d s connected to a 

normal 120  V A C or  2 4 0 V  A C  5 0 / 6 0 Hz line  s o u r c e . 

W A R N I N G 

T H I S  S E C T I O N  O F  T H E  M A N U A L 

C O N T A I N S  S E R V I C E  I N S T R U C T I O N S 

F O R  U S E  B Y  Q U A L I F I E D  S E R V I C E 

P E R S O N N E L ONLY. 

F I G U R E  1 0 ,  R E V E R S E  R I A A 

E Q U A L I Z A T I O N  N E T W O R K 

D O

  N O T  U S E  S H I E L D E D  C A B L E  A T  T H E  O U T P U T  O F 

T H E  F I L T E R ;  S T R A P  D I R E C T L Y  T O  T H E  I N P U T  O F 

T H E  V O L T M E T E R , 

A C  V O L T M E T E R 

To

 MIC 

CHANNEL 
UNDER TEST 

F I G U R E  1 2 ,  4 0  d B , 

6 0 0

 n

  P A D 

The following test equipment is  r e c o m m e n d e d : 

A U D I O  T E S T  O S C I L L A T O R 

H A R M O N I C  D I S T O R T I O N  A N A L Y Z E R 

40  d B PAD [150 O) 

R E V E R S E RIAA  E Q U A L I Z A T I O N  N E T W O R K 

20 kHz  F I L T E R 

A L T E R N A T E  4 0  d B  P A D  [ 6 0 0

 O) 

Krohn-Hite 4100, or equivalent. 

Hewlett-Packard model  3 3 3 A , or equivalent. 

S e e Figure 9 

S e e Figure 10 

S e e Figure 11 

S e e Figure 12 

Figure 8. 

F I G U R E  9 ,  4 0  d B , 

1 5 0

 n

  P A D 

H E W L E T T 

P A C K A R D 

3 3 3 A  O R 

3 3 1 A 

F I G U R E  1 1 ,  2 0  K H Z  F I L T E R 

A L T E R N A T E  O S C I L L A T O R  S E T U P :  Z =  6 0 0 n 

2 0  K H Z  F I L T E R 

O S C I L L A T O R  I N 

To  P H O N O  I N 

150 A BAL 

K R O H N -  H I T E 

4 1 0 0 

To

  M I C 

C H A N N E L 

U N D E R  T E S T 

O S C I L L A T O R 

4 0

 dB

  P A D 

K R O H N -  H I T E 

4 1 0 0 

O S C I L L A T O R 

4 0

 dB

  P A D 

Reviews: