background image

16

Safety

It is imperative to follow safety guidelines to protect health and prevent electric 
shock, injury, fire or explosions. 

- Do not use the units for any purpose other than PCB preheating. Incorrect use may cause fire.

- The mains cable must be plugged into approved bases. Make sure that it is properly grounded 
  before use. When unplugging it, hold the plug, not the wire.

- The temperature of accessible surfaces may remain high after the unit is turned off. Handle with care.

- Do not leave the appliance unattended when it is on.

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.

- Heat can cause inflamable products to ignite even when out of sight.

- Be careful with the remains of liquid tin. In contact with skin, it can cause burns.

- Avoid flux coming into contact with skin or eyes to prevent irritation.

- Be careful with the smoke produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when  
  working to avoid personal harm.

- This appliance can be used by children over the age of eight as well as persons with reduced 
   physical, sensory or mental capabilities or lacking experience provided that they have been given
  adequate supervision or instruction concerning use of the appliance and understand the hazards  
  involved. Children must not play with the appliance. 

- Maintenance must not be carried out by children unless supervised.

Summary of Contents for XL Preheater Set

Page 1: ...XL Preheater Set Ref PHXLE KA INSTRUCTION MANUAL www jbctools com...

Page 2: ...ape 1 unit Ref PH217 Manual 1 unit Ref 0026284 XL Preheater PCB Support 1 unit Ref PHXL SA Heater Unit Console XL Preheater 1 unit Ref PHXLE 1A 120V PHXLE 2A 230V PHXLE 9A 100V RJ45 Cable 1 unit Ref 0...

Page 3: ...nnector to Console RJ12 Connector to Robot Thermocouple Connectors x8 Type K Console 2 8 Color TFT Screen Start Stop USB B Connector RJ45 Connector to Heater Unit USB A Connector Foot for vertical Set...

Page 4: ...Three phase 230V 30 A 10 A 4mm2 1 mm2 100V 120V 60 A 20 A 10 mm2 2 5mm2 PHXLE A can be connected to single phase or three phase networks A power supply cable is required Use the following table to de...

Page 5: ...ater Unit do as follows 1 Unscrew the four screws and remove the cover The cable can be inserted through the front or the side part of the Heating Unit all you have to do is replace the cap with the c...

Page 6: ...03 for your working level Arrange the selected supports between the PCB and the Preheater to stabilize the PCB so as to avoid PCB deformatiion Low level High level Medium level 28 mm 38 mm 48 mm To ch...

Page 7: ...lift out the PCB Fast PCB Replacement The support lets you replace PCBs of the same batch fast and easily Use the sliding guides to change the PCBs Removing the PCB Placing another PCB Sliding guide k...

Page 8: ...n overall station reset restoring all the parameters to their default values Profile Editor Menu Options Station Information Instant power supplied to heater Status indicator Status bar Thermocouple s...

Page 9: ...te for Printed Circuits and is committed to becoming the most recognized international industry association for the electronics manufacturing industry Fix with Kapton Tape Protection Thermocouple Sett...

Page 10: ...d power as long as the thermocouples do not reach the control protection temperature limit Thermocouple current temp Thermocouple selected temp and mode Control Protection Info Instant power supplied...

Page 11: ...e without connecting the Thermocouple TC The heating process will be the same as long as the same working conditions are respected The profiles which already have the data from the Teach profile are m...

Page 12: ...es There are 3 profiles predefined by JBC A B and C The difference between them is the number of steps 2 3 or 4 The thicker your PCB is and the more layers it contains the more steps are needed to obt...

Page 13: ...is connected Station is controlled by a PC Station is controlled by a robot System Notifications Station software update Press INFO to start the process Warning Press INFO for failure description Err...

Page 14: ...File from www jbctools com software html and save it on a USB flash drive Preferably one with no other files JBC Update File 2 Insert the USB flash drive to the console The icon is diplayed while upda...

Page 15: ...leaning Alcohol can only be used to clean the metal parts Only if it is absolutely necessary and if cleaning with isopropyl alcohol IPA is not enough it is recommended to use a scraper to remove dirt...

Page 16: ...nite Heat can cause inflamable products to ignite even when out of sight Be careful with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or e...

Page 17: ...Notes 17 www jbctools com...

Page 18: ...Notes 18...

Page 19: ...ment Thermocouple type K JBCset temperature profiles 3 profiles 2 3 or 4 steps User Profiles 22 up to 6 steps for each Maximum work time 600 min or indefinite Dimensions Weight 790 x 664 x 42 mm 18 kg...

Page 20: ...warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be...

Reviews: