background image

10

Maintenance

Fuse

- Replace any defective or damaged pieces. Use original JBC spare parts only. 

- Repairs should only be performed by a JBC authorized technical service.

Before carrying out maintenance or storage, always allow the equipment to cool and unplug the stand 
from the station and the tool.

- Clean the station screen with a glass cleaner
   or a damp cloth.

- Use a damp cloth to clean the casing, the  

stand and the tool. Alcohol can only be  
used for cleaning the metal parts.

- Periodically check that the metal parts of the 

tool and stand are clean so that the station 
can detect the tool status.

- Maintain tip surface clean in order to ensure a 

correct stripped wire.

- Periodically check all cables.

- Replace a blown fuse as follows (see 
specification chart) :

1.

 Take out the fuse holder and remove the 

fuse. If necessary use a tool to lever it out.

2. 

Press the new fuse into the fuse holder and 

reinsert it in the station.

Clean 
periodically

WSBT 
Stand for 
WS440

(not included)

Fuse

Fuse Holder

Fuse Holder

WSST 
Stand for 
WS140

(not included)

Summary of Contents for WS-9UA

Page 1: ...INSTRUCTION MANUAL WS High Temperature Wire Stripper Control Unit...

Page 2: ...unit Ref 0024092 100V 0023715 120V 0023714 230V Packing List The following items are included This manual corresponds to the following references WS 9UA 100V WS 1UA 120V WS 2UA 230V Features Power So...

Page 3: ...Main Switch Fuse Stand Cable Ref 0024227 WSST Stand for WS140 High Temperature Precision Wire Stripper Tweezers WS140 High Temperature Precision Wire Stripper Tweezers W140 Blade Cartridges not inclu...

Page 4: ...ntrol Unit Equipotential connector USB Connector Main Switch Fuse Stand Cable Ref 0024227 WSBT Stand for WS440 High Temperature Wire Stripper Tweezers WS440 High Temperature Wire Stripper Tweezers W44...

Page 5: ...C o PI Temp Hibernation Menu Work Mode Power OFF min o o min 1 2 3 4 Fix Level Sleep delay Hibernation delay Menu Work Mode Power OFF min o o min 1 2 3 4 Fix Level Sleep delay Hibernation delay Beep...

Page 6: ...de Power OFF min o o min 1 2 3 4 Fix Level Sleep delay Hibernation delay Temp Power 59 Custom68 Power 35 Kapton Sleep 90 PI Power 0 Kapto PI Predefined Values Customizable Value WS offers two differen...

Page 7: ...o C o PI Temp Hibernation Power OFF min o o min Menu Work Mode Power OFF min o o min 1 2 3 4 Fix Level Sleep delay Hibernation delay ON OFF R Power Menu Work Mode Power OFF min o o min 1 2 3 4 Fix Lev...

Page 8: ...ctivate them and strip the wire Once the pedal is released the wire stripper enters in Hibernation To reverse the pedal functionality flip the switch of the connection box Default PIN 0105 WS140 High...

Page 9: ...on at www jbctools com Align cartridges with JBC s pliers Remove cartrigdes with JBC s Cartridge Extractor Pliers Ref PLR195 Removing Inserting and Positioning Flat Screw Driver Cartridge Extractor Pl...

Page 10: ...tool Alcohol can only be used for cleaning the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface...

Page 11: ...enance must not be carried out by children unless supervised Place the tool on the stand when is not in use Turn off the power when not in use changing parts or storing Caution Do not use the Wire Str...

Page 12: ...year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase para manuales color gris 0030997 110723 Specifications WS High Temperature Wire Stripper Con...

Reviews: