10
Maintenance
Fuse
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
Before carrying out maintenance or storage, always allow the equipment to cool and unplug the stand
from the station and the tool.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Use a damp cloth to clean the casing, the
stand and the tool. Alcohol can only be
used for cleaning the metal parts.
- Periodically check that the metal parts of the
tool and stand are clean so that the station
can detect the tool status.
- Maintain tip surface clean in order to ensure a
correct stripped wire.
- Periodically check all cables.
- Replace a blown fuse as follows (see
specification chart) :
1.
Take out the fuse holder and remove the
fuse. If necessary use a tool to lever it out.
2.
Press the new fuse into the fuse holder and
reinsert it in the station.
Clean
periodically
WSBT
Stand for
WS440
(not included)
Fuse
Fuse Holder
Fuse Holder
WSST
Stand for
WS140
(not included)