A
B
Connections
Connection
to
UCR
Gripper Actuator
Fluid
Air
Applicable tubing
Ø4mm
Operating pressure
1,5 to 7 bar
20 to 100 psi
A
Air tube connection: Close arm to soldering position.
B
Air tube connection: Open arm to service position.
C
D
C
Air tube connection: Close grippers.
D
Air tube connection: Open grippers.
Note:
JBC recommends bi-stable valves for the grippers to prevent the cartridge from falling out in
case of an emergency stop or power cut.
4