3
1.
Pull out the sensor
2.
Adjust at an ambient temperature
with slotted screw driver.
3.
Wiring like the drawing below.
4.
Apply a voltage of 23.65mV and verify the temperature shown in the thermometer is 350°C (662°F)
5.
Take note of the deviation to correct future measurements.
6.
Insert the sensor ST-A.
NOTES:
- Thermometer can be adjusted through the potentiometer you will find inside the unit.
- The calibration date is on the label on the bottom
Digital
mVolt Meter
TI-A
Variable
power supply
ST-A
CALIBRATION OF TI-A
2
+
-
-
-
+
+
1