background image

5

Select

Profile

Step 

4

Time 

20

Temp  450

Air 

100

º

C

º

C

Edit Profile

Edit Profile 8

8

ORIGINAL PIN: 0105

Main menu

Settings

Counters

1        Reset settings
2       Station Settings

3

       Profile Settings

4       Counters

5        Program version

1     Temp unit

                

 Celsius

  

 Maximum temp     450

0

C

3

    Minimum temp         T OFF

4   Fix temp                    400

0

C

5    Max air                        100%
6    Min air                             10%
7    Fix air                             40%
8    Time to stop           120 sec
9    Beep                                     ON
10  Pop up                                 ON
11   Change PIN

1       Station ON hou

rs        

            0

2   Works hours                0

3

     Works cycles                      0

Exit

Back

Back

Exit

SETTINGS

*

* Selecting Tmin to “T OFF” allows 
for blowing at ambient temperature.

Profile settings

1       

 

Profiles

2       Edit Profile

3

       Copy profile

Exit

Summary of Contents for TE Series

Page 1: ...TE PRECISION HOT AIR STATION www jbctools com...

Page 2: ...TN9209 3 TN9208 4 TN9080 5 NOZZLE 0930110 SUCTION CUPS 0932330 SUCTIONTUBE T2050 20 T2250 40 TRIPOD POWER CORD These accessories not supplied withTE 2QB TE 1QB TE 9QB stations Protector P2220 32 P2230...

Page 3: ...ay USB connector to PC Update station software Create graphs of the soldering process Manage and monitor parameters via PC Function keys Connectable tools JT T2A JT T1A TE TB Heating element Hot Air s...

Page 4: ...5 seconds Profile 8 Power 70 400 380 80 Selected temperature Current temperature Instant power supplied to heater Selected profile Current temperature Selected flow Graph of selected profile Remaining...

Page 5: ...m version 1 Temp unit Celsius 2 Maximum temp 4500 C 3 Minimum temp T OFF 4 Fix temp 4000 C 5 Max air 100 6 Min air 10 7 Fix air 40 8 Time to stop 120 sec 9 Beep ON 10 Pop up ON 11 Change PIN 1 Station...

Page 6: ...he last point of the profile by selecting in the time parameter It should be taken into account that the regulation range permitted by the station is between 150 C and 450 C whereby it is not possible...

Page 7: ...the heating element set is cold 1 Untighten screw 2 Separate the heating element from the heating set s handle 3 Connect new heating element pushing it s extreme 4 Insert screw to aviod air loss witc...

Page 8: ...NS Temperature selection from room temperature to 450 C 850 F and cool mode can be used to blow air at room temperature Ambient Operating Temperature 10 to 40 C 50 104 F Output Peak Power 300W Air flo...

Reviews: