Temp
º
C
º
C
Program 8
380
Air
100%
Time 125s.
13
Decrease program
number
Increase program
number
Selected program
Current temperature
Selected air flow
Graph of selected
program
Remaining time
Program Mode
Program Options
Edit Program
This option allows you to edit or create a program.
First, you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting “-----” in the time parameter.
It should be taken into account that the regulation range permitted by the station is 150-450°C, whe-
reby it is not possible to create temperature ramps between room temperature (Toff) and 150°C.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and its destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
www.jbctools.com
Summary of Contents for RMSE-C
Page 66: ...66 Exploded View Despiece ...