Recommended Guidelines
1.
Place the Control Thermocouple as near as possible to the component being worked on.
2.
If there are any sensitive components, use a Thermocouple as protection.
You can select the protection temperature in the
Thermocouples
menu
.
If the selected temperature
is reached, the Heater Unit will stop the process and a warning message will be shown.
3.
IPC* does not recommend exceeding ramp-up rates over 3 - 4 °C / sec (5 - 7 °F / sec) so as to
reduce the risk of thermal stress on the PCB.
* IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits and is committed to becoming the
most recognized international industry association for the electronics manufacturing industry.
Fix with Kapton Tape
Protection
Thermocouple
Setting Thermocouples Function
Select
Thermocouples
from the
Work mode
menu to set them up.
The thermocouples (TC) can work in three diferent ways depending on what is needed.
· Control: the unit mantains the selected temperature.
· Protection: the Heater Unit stops if the TC reaches the selected temperature.
· Info: the TC temperature is shown in the work screen.
The TC1 is always working in Control mode for the
Temperature
mode as well as for
Profiles
mode.
The temperature of each TC can also be selected from the work screen.
Control
Thermocouple