background image

6

Profiles by Temperature

The usual way to run a profile is using the Thermocouple (TC) connected to the Control Input of the 
console. JBC offers 3 predefined profiles (JBCset) and 20 profiles ready for you to personalize.

Why convection? Perfect heat distribution

Convection technology offers a uniform heat distribution over the whole working area of the 
Preheater. This gradual heating system reduces the risk of thermal stress on the PCB.

Operation

JBCset profiles

There are 3 profiles predefined by JBC: A, B and C. The difference between them is the number 
of steps: 2, 3 or 4. The thicker your PCB is and the more layers it contains, the more steps are  
needed to obtain a gradual warming.
These profiles are not modifiable but they can be used as a template to create your own profiles.

JBCset A

2 steps

JBCset B

3 steps

JBCset C

4 steps

For repetitive jobs 

we recommend

 running profiles without the Thermocouple (TC). Once any 

profile has been run to the end, the system has all the process data which you can save.
Once it is saved, you can run this profile without connecting the Thermocouple (TC). The heating 
process will the same as long as the same working conditions are respected.

User profiles

You can create your own profiles from the JBCset profiles. On the work screen of the profile, 
press the 

Enter

 button and choose the option 

Edit profile.

Power or Temperature Modes

The unit works at the selected power or temperature during the defined time. These parameters can 
be modified from the work screen by pressing the 

Enter

 button and the 

Edit parameters 

menu

.

To see the current temperature you must plug the Thermocouple (TC) into the Control connector.

PCB reference 

specifications:

FR4 1,6mm thick 

and 2 layers.

FR4 2,2mm thick 

and 6 layers.

FR4 1,6mm thick 

and 6 layers.

Profiles set using the low position of the PHB-SA Support (28 mm in height between the PCB and the heating area).

Summary of Contents for PHB-1KA

Page 1: ...Espa ol 11 Convection Preheater Set Ref PHB KA English 2 Page INSTRUCTION MANUAL www jbctools com...

Page 2: ...9417 100V 120V 0009401 230V Thermocouple 1 unit Ref PH218 Kapton Tape 1 unit Ref PH217 Manual 1 unit Ref 0016815 Ref PHB KA Convection Preheater Set Convection Preheater 1 unit Ref PHB 1A 120V PHB 2A...

Page 3: ...s Power socket Power Fixing brackets for PHB SA Convection Preheater Support Heater Unit Console Control Unit Start Stop Auxiliary Thermocouple Type K Input Thermocouple Type K Ref PH218 USB B connect...

Page 4: ...ghts between the PCB and the Heating Area of the PHB A Heater Unit Low level High level Medium level 28 mm 38 mm 48 mm PHB SA Features Adjustable slot clamps for switching PCBs Adjusting system for ch...

Page 5: ...the sliding guides to change the PCBs Position it and tighten the sliding guide knobs Removing the PCB Placing another PCB Cap Guide PCB Use the 4 caps to place larger PCBs than the PHB SA Support or...

Page 6: ...petitive jobs we recommend running profiles without the Thermocouple TC Once any profile has been run to the end the system has all the process data which you can save Once it is saved you can run thi...

Page 7: ...s reached the Heater Unit will stop the process and a warning message will be shown 3 IPC does not recommend exceeding ramp up rates over 3 4 C sec 5 7 F sec so as to reduce the risk of thermal stress...

Page 8: ...8 Display Control...

Page 9: ...9 www jbctools com...

Page 10: ...cleaning Alcohol can only be used to clean the metal parts Only if it is absolutely necessary and if cleaning with isopropyl alcohol IPA is not enough itisrecommendedtouseascraper to remove dirt in th...

Page 11: ...can cause inflamable products to ignite even when out of sight Be careful with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or eyes to pr...

Page 12: ...Power 1800W 1800W 1400W Heating Area 180 x 277 mm 7 1 x 10 9 in 1 zone 360 x 277 mm 14 2 x 10 9 in 2 zones Temperature Range 50 250 C 120 482 F Temperature Measurement Thermocouple type K JBCset tempe...

Page 13: ...Set Precalentador de Convecci n Ref PHB KA 13 www jbctools com...

Page 14: ...Soporte para Precalentador PHB 1 unidad Ref PHB SA Thermocouple Termopar Tipo K 1 unidad Ref PH218 Kapton Tape Cinta Kapton 1 unidad Ref PH217 Manual 1 unidad Ref 0016815 Convection Preheater Precale...

Page 15: ...oras Toma de Red Interruptor general Fijadores para el soporte PHB SA Unidad de Control Bot n Inicio paro Conector para Termopar auxiliar Tipo K Termopar Tipo K Ref PH218 Conector USB B a PC Actualice...

Page 16: ...justar 3 alturas entre el PCB y el rea calefactora Nivel Bajo Nivel Alto Nivel Medio 28 mm 38 mm 48 mm PHB SA Caracter sticas Abrazaderas ajustables para intercambiar PCBs Sistema de ajuste de alturas...

Page 17: ...ntercambiar los PCBs manteniendo fija la guia deslizante Posicione el nuevo PCB y vuelva a fijar la gu a Retirar el PCB Colocar el nuevo PCB Tap n Gu a PCB Utilice los cuatro tapones para colocar PCBs...

Page 18: ...forme y progresivo Estos perfiles no son modificables pero pueden ser usados como plantilla para crear sus propios perfiles User Profiles Perfiles de Usuario Puede crear sus propios perfiles a partir...

Page 19: ...settings Si la temperatura llega a la establecida se interrumpir el proceso y mostrar un warning 3 IPC no recomienda exceder tasas de rampas por encima de los 3 4 C seg 5 7 F seg con el fin de reduci...

Page 20: ...Pantallas de control 20...

Page 21: ...21 www jbctools com...

Page 22: ...a las partes met licas Solo cuando sea absolutamente necesario y si la limpieza con isopropanol IPA no es suficiente se ecomienda el uso de una rasqueta para limpiar la suciedad adherida en la zona de...

Page 23: ...o En contacto con la piel puede causar quemaduras Evite el contacto del Flux con la piel o los ojos para prevenir la irritaci n Tenga cuidado con el humo producido al trabajar Mantenga su lugar de tra...

Page 24: ...7 6 x 1 6 in Potencia m xima 1800W 1800W 1400W rea calefactora 180 x 277 mm 7 1 x 10 9 in 1 zona 360 x 277 mm 14 2 x 10 9 in 2 zonas Rango de temperatura 50 250 C 120 482 F Medici n de temperatura Ter...

Page 25: ...25 Notes www jbctools com...

Page 26: ...26 Exploded View Despiece...

Page 27: ...27 www jbctools com...

Page 28: ...ctr nicos al final de su vida se deber n recoger y trasladar a una planta de reciclaje autorizada 0016815 0817 Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects in...

Reviews: