7
FOLLOW THIS PROCESS INVERTED TO RE-CONNECT THE HEATING ELEMENT
This step has to be performed when the tool is stopped and the heating set is cold.
1. Untighten screw.
2. Separate the heating element from the heating set’s handle.
3. Connect the new heating element, pushing it’s extreme.
4. Insert screw to avoid air-loss which could reduce the heating element’s lifetime.
0014107
(230V) or
0014105
(100V-120V)
Heating element
0009829
Handle
JT-T2A
(230V) or
JT-T1A
(100V-120V)
Heating set
REPLACING THE HEATING ELEMENT
CHANGING THE HEATING SET
1. Ensure that the tool is stopped
2. Use a wrench to unscrew the cover
3. Pull back the seal
4. Pull connector from the socket to disconnect
the heating set from the station
5. Follow steps in reverse
to connect the heating set