Maintenance - Filter replacement
- The unit notifies through both the display and
the LED when filters need maintenance.
- To replace the filters, first turn the fume
extractor off. Then remove the cover by
opening the quick release lever of the casing
(image 1).
- If once the pre-filter has been changed the
saturation indicator is on, it means that the
compact filter is already saturated and must
be replaced too.
- The duration of the compact filter is 1 year
maximum once its packaging is opened.
- Once the compact filter has been replaced,
the filter counter must be reset.
(Main Menu > Filter set > Reset carbon)
- If the display shows an error when the
equipment is switched on, it is probable that
the cover and casing connectors (image 2)
are dirty and making false contact. Remove
the cover and clean both connectors.
- If the filter is changed while the fume extractor
is on, once the cover is placed the equipment
starts an automatic filter detection process: the
work valves open, the stand valves close and
the fume extractor suctions for a few seconds.
Important:
Read the page 2 before using the fume extractor.
Pre-filter
Ref. FAE2-110
Compact filter
+ Pre-filter
Ref. FAE2-100
Image 1
Image 2
www.jbctools.com
15