background image

Main menu

Exit

1 Reset
2  Unit

3

  Port

4 Filter set
5 Counters
6  Program version

Filter set

Carbon life 

80%

2  Saturation  

20%

3

  Reset carbon

Back

STOP 

#

1

Useful filter life is worn out. 

Replace it and execute reset 

function in the filter menu.

STOP 

#

3

Filter not detected. Place 

a filter in order to use the 

fume extractor.

STOP 

#

2

Filter obstructed. Replace 

the pre-filter, if the error 

remains, replace the 

HEPA+carbon filter set.

WARNING 

#

1

Useful filter life is about to 

wear out. In X days the filter 

life is going to finish.

WARNING 

#

2

Filter is about to obstruct.

Filter set

1  Carbon life

 

80%

2

 Saturation

  

20%

3

  Reset carbon

Back

Filter set

1  Carbon life

 

80%

2  Saturation  

20%

3

 

 Reset carbon

Back

Control Process

Filter Menu

Warning & Errors

Shows % of remaining life of the 
carbon filter contained inside the 
main filter. It is also displayed on 
the main screen.

Perform this action when changing 
the HEPA + carbon set filter. The 
carbon life counter doesn’t start 
until the filter is detected for the 
first time.

The unit notifies when filters need maintenance.

The unit stops working when filters have to be replaced.

Shows % of saturation level of 
HEPA + carbon filter set. It is also 
displayed on the main screen.