Summary of Contents for DMVE-1A

Page 1: ...Premium 4 Tools Rework station with Pneumatic Pump Ref DMVE A www jbctools com...

Page 2: ...Pneumatic Desoldering Module 1 unit Ref MVE A Tip Cleaner 1 unit Ref CL9885 Module Cable 1 unit Ref 0014874 DME Control Unit 1 unit Ref DME 1A 120V DME 2A 230V DME 9A 100V Union Flanges 1 unit Ref 00...

Page 3: ...unit Ref 0965970 Filter Box 1 unit Ref 0780840 It contains 10 filters Spanner 1 unit Ref 0780550 Tin deposit 1 unit Ref 0812620 Long Tip Cleaning set 1 unit Ref 0965760 Metal tin diposit 1 unit Ref 0...

Page 4: ...Ref AD SD General Purpose Handle Ref T245 A Desoldering Iron Ref DR560 A Cartridge Ref C245903 Ref C245906 Tip Ref C560004 Ref C560005 Ref C560013 Stand Ref DR SD Stand Cable Ref 0011283 RJ12 connect...

Page 5: ...Ref MVE A To another peripheral To Pedal Ref P 005 USB A connector 3 5 Color TFT Touch screen Tilt the display for easy reading Suction Filter Ref 0821830 Module Cable Ref 0014874 Speaker Air pressur...

Page 6: ...artridges without interrupting your work Adjustable tool holder Suits your work position Adjustable cable collector Adjustable Stands Stand Ref DR SD Quick tip changer Holding tip system for easy chan...

Page 7: ...vent oxidation between cleaning and rewetting It prevents splashing of solder particles when using the brass wool Heavy weighted non slip base for simple handed cleaning The least harmful cleaning met...

Page 8: ...s follows A For straight C210 B For curved C210 C For curved C245 D For straight C245 Important It is essential to insert the cartridges as far as the mark for a proper connection B C A D Compatible c...

Page 9: ...max pin 0 6 C560 003 A 2 7 B 1 max pin 0 8 C560 004 A 3 2 B 1 3 max pin 1 1 C560 009 A 5 B 1 3 max pin 1 1 C560 014 A 2 5 B 0 8 max pin 0 6 1 Removing Unscrew the tip using the spanner supplied 2 Ins...

Page 10: ...the screw as shown and remove the Heating Element 3 Placing Place the new Heating Element and follow the steps conversely 2 1 3 To perform this operation turn off the station or disconnect the tool Im...

Page 11: ...d and replaced if dirty or damaged Remove the coil to clean the inside of the deposit with the stick supplied The lid must be removed with the DR560 in vertical position The deposit must be inserted w...

Page 12: ...s are left on a terminal after desoldering it resolder it with fresh solder and repeat the desoldering operation When the solder liquefies gently rotate the tip so that the compo nent terminal can be...

Page 13: ...the Peripherals Menu and select the port which you want to join with the module MVE Changing the pump filters Use a damp cloth to keep the casing clean Periodically check all cable and tube connection...

Page 14: ...is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand the temperature falls to the preset Sleep temperature After longer periods of inactivity the po...

Page 15: ...livered for each port Tool in use Press here to see the Ports Screen Cartridge in use Introduce the reference for more precise temperatures readings Station Lock PIN required for unlocking See the inf...

Page 16: ...een Utilities Select any option and press the station information button to display each parameter description Useful additional applications that complement and support your work View your video via...

Page 17: ...Indicates there is a peripheral to be installed After connecting the tool introduce the last 3 reference numbers of the cartridge Insert the cartridge model and the station will recognize its characte...

Page 18: ...ch tip to use to obtain the best quality soldering Process analysis Export graphics Insert a USB flash drive into the USB A connector to save your soldering process in csv format Graphics Temperature...

Page 19: ...specific configurations for later uses Analyze the soldering graphics of the stations on your PC and export them 1 Download the JBC Manager software and the user manual from www jbctools com manager...

Page 20: ...nect the other PSE s as follows Centralize control of 3 PSE Power Supply Units in a single DME and work with as many as 16 tools simultaneously Increase x4 your DME s possibilities Four Tool Control U...

Page 21: ...o the Robot Communication Protocol available on the website www jbctools com jbcsoftware menu 115 html Manage and monitor the station using a Robotic system Working with Robots Control Unit Robot Upda...

Page 22: ...and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fuse holder and replace it in the station Use a damp cloth to clean the casing and the tool Alcohol can only b...

Page 23: ...appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Use a non residue classified flux and avoid contact with skin or eyes to prevent irr...

Page 24: ...ol Temperature Range 90 450 C 190 840 F Idle Temp Stability still air 1 5 C 3 F Ambient Operating Temperature 10 40 C 50 104 F Tip to ground resistance 2 ohms Tip to ground voltage 2mV RMS USB A USB B...

Page 25: ...www jbctools com 25...

Page 26: ...Exploded View Despiece Explosionszeichnung 26...

Page 27: ...www jbctools com 27...

Page 28: ...roduct wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In...