Clean periodically
Maintenance
Before carrying out maintenance or storage, always allow the equipment to cool.
1.
Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
2.
Insert the new fuse into the holder and
return it to the station.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Use a damp cloth to clean the casing and the
tool. Alcohol can only be used to clean the
metal parts.
- Periodically check that the metal parts of the
tool and stand are clean so that the station
can detect the tool and establish its status.
- Maintain tip surface clean and tinned prior to
storage in order to avoid tip oxidation. Rusty
and dirty surfaces reduce heat transfer to the
solder joint.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
Fuse holder
Fuse
Fuse Holder
10